550267
23
Zoom out
Zoom in
Previous page
1/52
Next page
23
English
ALADIN SQUARE USER MANUAL
NOTE: more about diving with the MB
levels, read chapter: Diving with MB levels.
1.3.4 Setting the Safety stop timer
By pressing SEL at this menu the function at
bottom row will start blinking and by pressing
right or left following options may be selected:
Off = safety stop timer is not activated
Push = safety stop timer will start at the end
of the dive with button press
Auto = safety stop timer will start automatic
when the depth at the end of the
dive becomes less than 5m/15ft
and all decompression or MB stops
have been accomplished.
By pressing SEL the function is confi rmed and
the time starts blinking. By pressing right or
left you the value may be selected from 1 to 5
minutes. By pressing SEL the time is confi rmed.
1.3.5 Set HR limits
(Workload settings)
By pressing SEL in this menu the HR high
value starts blinking. By pressing right or
left the value can be changed from 140 up
to 220. This is your maximum heartbeat
setting, when you are for example diving
against the current. By pressing SEL the
low value starts blinking. By pressing right
or left the value can be changed from 60
up to 120. This is your heartbeat when you
are relaxed in the water and for example
holding from the anchor line. By pressing
SEL again the limits are confi rmed.
NOTE: Diving experience and sport
exercises have an effect to your heart rate
limits during diving. You may need to edit
the limits after you have used your Square
for some time. If you want to learn more
about the heart rate related to diving, you
may read a SCUBAPRO booklet 2012:
Dr. Uwe Hoffmann, Dr. Tobias Dräger,
“Sicherer Und Besser Tauchen Mit
Herzfrequenzmessung.
NOTE: Refer to chapter HR enable to
learn how HR function can be enabled.
1.3.6 Set the PDI Stop
By pressing SEL the PDIS function starts
blinking. By pressing right or left the value
can be set to on or off. By pressing SEL the
setting is confi rmed.
NOTE: To learn more about diving with
PDI stop, read the chapter PDI Stops.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scubapro Aladin Square at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scubapro Aladin Square in the language / languages: English as an attachment in your email.

The manual is 2,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info