GB
Other types of connection
! The cable provided is not suitable for the following
types of installation.
If the mains supply corresponds with one of the
following:
Voltage and mains frequency
 400V 3 - N ~ 50 Hz
 400V 2 - N ~ 50 Hz
 230V 3 ~ 50 Hz
 230V 2 + 2 - N ~ 50 Hz
proceed as follows:
1. Use a suitable supply cable, H05RR-F or higher, with
the right dimensions (cable section: 1.5 mm).
2. To open the terminal board, insert a screwdriver into
the side tabs of the cover (see Terminal board picture).
3. Loosen the cable clamp screw and the terminal board
screws according to the type of connection required and
position the connection supports as shown in the
following table and diagrams.
4. Position the wires according to the following table and
diagrams and connect the appliance by tightening all
the screws for the springs as much as possible.
5. Secure the power supply cable by fastening the
clamp screw then put the cover back on.
Connecting the supply cable to the mains
If the appliance is being connected directly to the mains
an omnipolar circuit-breaker must be installed with a
minimum opening of 3 mm between contacts.
! The installer must ensure that the correct electrical
connection has been made and that it is compliant with
safety regulations.
Before connecting to the power supply, make sure that:
The appliance is earthed and the plug is compliant
with the law.
The socket can withstand the maximum power of the
appliance, which is indicated on the attached data
plate.
The voltage is in the range between the values
indicated on the data plate.
The socket is compatible with the plug of the
appliance. If the socket is incompatible with the plug,
ask an authorised technician to replace it. Do not use
extension cords or multiple sockets.
! Once the appliance has been installed, the power
supply cable and the electrical socket must be easily
accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced by
authorised technicians only.
! The manufacturer declines any liability should these
safety measures not be observed.
L1
L2
N2N1
1 2 3 4
5
L1 L2 L3
1 2 3 4 5
L1 L2 N
1 2 3 4 5
Phase
Neutral
EarthPhase
Neutral
U-bolt
connection support
5
1
2
3
4
5
1
2
3
4
U-bolt
connection support
Phase PhasePhase Neutral Earth
5
Phase Neutral
U-bolt
connection support
Earth
1
2
3
4
Phase
5
Phase Phase
U-bolt
connection support
Earth
1
2
3
4
Phase
L1 L2 L3 N
1 2 3 4 5
Two-phase
Three-phase 400
Three-phase 400 2+N
Three-phase 230
Voltage and
mains
frequency
Electrical connections
Terminal
board
400V 3-N ~
50 Hz
Three-phase
400
400V 2-N ~
50 Hz
Three-phase
400 2+N
230V 3 ~ 50 Hz
Three-phase
230
230V 2+2-N ~
50 Hz
Two-phase
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scholtes tt 6234 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scholtes tt 6234 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 2,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Scholtes tt 6234

Scholtes tt 6234 User Manual - Dutch - 11 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info