with current safety standards.
Important: To insure that the appliance operates safety,
the gas is regulated correctly and your appliance lasts
over time, make sure that gas pressure levels comply with
the indications given in Table 1, “Nozzle and Burner
Specifications”.
Gas Connection to Non-flexible Pipe
(copper or steel)
Connection to the gas source must be done in such a way
as to not create any stress points at any part of the
appliance.
The appliance is fitted with an adjustable, "L" shaped
connector and a gasket for the attachment to the gas
supply. Should this connector have to be turned, the gasket
must be replaced (supplied with the appliance).
The gas feed connector to the appliance is a threaded,
male 1/2" connector for round gas pipe.
Gas Connection to Flexible Steel Pipe
The gas feed connector to the appliance is a threaded,
male 1/2" connector for round gas pipe. Only use pipes,
tubes and gaskets that comply with current safety codes.
The maximum length of the flexible pipes must not exceed
2000 mm. Once the connection has been made, ensure
that the flexible metal tube does not touch any moving
parts and is not crushed.
Check the Seal
Once the appliance has been installed, make sure all the
connections are properly sealed, using a soapy water
solution. Never use a flame.
Adapting the Cooktop for Different Types of Gas
To adapt the cooktop to a different type of gas than that
for which it was designed, (see the sticker under the hob
or on the packaging), the burner nozzles must be changed,
as follows:
Remove the pan supports and slide the burners out of
the cooktop.
Unscrew the nozzles using a 7mm socket wrench and
replace them with those for the new type of gas. (See
table 1, “Burner and Nozzle Specifications”).
Reassemble the parts following the instructions in
reverse order.
On completing the operation, replace the old rating label
with the one showing the new type of gas; the sticker
is available from our Service Centres.
If the gas pressure is different than that prescribed, a
pressure regulator must be installed at the source, in
compliance with national standards governing the use of
piped gas regulators.
Regulation of Air Supply to the Burner
The burners do not need a primary air regulator.
Minimum Regulation
Turn the gas valve to minimum.
Remove the knob and turn the regulator screw
(positioned either on the side of the top or inside the
shaft) clockwise until the flame becomes small but
regular.
N.B.: In the case of liquid gas, the regulation screw must
be fully screwed in (clockwise).
Make sure that, when the knob is turned rapidly high
to low, the flame does not go out.
In the event of a malfunction on appliances with the
security device (thermocouple) when the gas supply
is set at minimum, increase the minimum supply levels
using the regulator screw.
Once the adjustment has been made, apply sealing wax,
or a suitable substitute, to the old seals on the by-pass.
Modification Stamp of the service centre Date
Attach one of the stickers in the
injector bag here
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scholtes tmg 7320 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scholtes tmg 7320 in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 1,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info