331465
42
Zoom out
Zoom in
Previous page
1/76
Next page
42
DE
BE
AT
Merkmale der Brenner und Düsen
* Bie 15°C und 1013 mbar-Trockengas
Propangas oberer Heizwert = 50,37 MJ/kg
Butan oberer Heizwert = 49,47 MJ/kg
(1) : nur für DEUTSCHLAND
I C A
C
B
D
A
C
A
PPF 20 65 - PPF 20 65 BNV - B 20 65/CS
PP 30TC 120 - PPF 30TC 120 - PPF 30TC 120 BNV -
B 30TC 120/CS
PPF 20DC 120 - PPF 20DC 120 BNV - B 20DC 120/CS
B
D
A
C
B 30TC 138/CS BNV
Tabelle 1 (DEUTSCHLAND - ÖSTERREICH) Flüssiggas Erdgas
Brenner ø
Brenner
(mm)
Leistung
kW (H.s.*)
By-pass
1/100
(mm)
Düsen
1/100
(mm)
Durchfluß*
g/h
Düsen
1/100 (mm)
Durchfluß*
l/h
Nom. Min.
G30/G31 G20 G25
(1)
G20 G25
(1)
C. Blitz 100 3.00 0.7 38 75 218 116 134 286 332
B. Schnell 75 1.65 0.4 30 58 120 96 100 157 183
A. Hilfs 55 1.00 0.4 30 45 73 71 77 95 111
D. mit Dreifachkrone 130 3.25 1.3 52 74 236 124 143 309 360
I. Doppelflammen (DC-DR inner) 30 0.90 0.4 30 40 65 70 75 86 100
I. Doppelflammen (DC-DR Außen)2 Dsen 130 4.10 1.3 52 60 298 110 123 390 454
Versorgungsdruck (mbar)
Nominal
Minimum
Maximum
50
42.5
57.5
20
17
25
20
18
25
Tabelle 1 (BELGIE) Flüssiggas Erdgas
Brenner ø
Brenner
Leistung
kW (H.s.*)
By-pass
1/100
Düse
1/100
Menge*
g/h
Düse
1/100
Menge*
l/h
(mm)
Nom. Red.
(mm)
(mm)
Butan Propan (mm)
G20 G25
(1)
C. Blitz 100 3.00 0.7 40 86 218 214 116 286 332
B. Schnell 75 1.65 0.4 30 64 120 118 96 157 183
A. Hilfs 55 1.00 0.4 30 50 73 71 71 95 111
D. mit Dreifachkrone 130 3.25 1.3 57 91 236 232 124 309 360
I. Doppelflammen (DC-DR inner) 30 0.90 0.40 30 40 65 64 70 86 100
I. Doppelflammen (DC-DR Außen )2 Dsen 130 4.10 1.30 57 70 298 293 110 390 454
Zufuhrdruck (mbar)
Nominal
Minimum
Maximum
28-30
20
35
37
25
45
21
17
25
25
20
30
Erdgas G20 oberer Heizwert = 37,78 MJ/m³
Erdgas G25 oberer Heizwert = 32,49 MJ/m³
! Die Kochmulde darf nur dann über Einbaubacköfen installiert werden, wenn diese über ein Kühlgebläse verfügen.
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scholtes pp 30tc120 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scholtes pp 30tc120 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 6,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info