2. Installation
WARNING! Do not lead the exhaust air into a chimney which is used
for extracting exhaust air of appliances operated by gas or other
combustibles.
1. For extracting the exhaust air always observe the current legal regulations.
2. The diameter of the exhaust hose must meet the diameter of the connecting ring.
3. If your appliance is equipped with a carbon filter, remove the carbon filter
before you operate the appliance in the extraction mode. The carbon filter
should be used in the recirculating mode only.
4. The exhaust duct should be as short and straight as possible. The diameter of
the exhaust hose should be at least 120/150 mm (look at chapter TECHNICAL
DATA). Otherwise you have to expect increased noise and decreased
performance of your appliance.
5. The proper maximum bending angle outwards is 120
0
.
6. Use smooth tubes or flexible, non-inflammable exhaust hoses only.
7. When the exhaust duct is connected horizontally, a minimum falling gradient of
1 cm/m or an inclination of 2
0
is required. Otherwise condensate will get into
the motor of the hood.
8. When an exhaust duct is used, the ending of the exhaust hose must be adjusted
into the direction of flow.
9. If the exhaust duct passes through cool areas (e.g. an attic), a temperature gradient
may occur in the different parts of the exhaust duct so condensate will be
generated. Proper insulation of the corresponding parts of the exhaust duct will
then be needed. Equip such an exhaust duct with a condensate trap if need be.
10. Depending on the model the hood is equipped with one (top) or two (top,
back) outlets.
11. The idle outlet is covered by a plastic cap. You can remove this cap by turning it
anticlockwise. Use the cap to cover the idle outlet.
2.1 Minimum distances
Strictly observe the minimum distance between hood and hob.
It is also absolutely necessary to observe the individual minimum
distances to extractor hoods which are specified in the instruction
manual of your hob / oven / etc.
33