Note the direction of rotation of the motor and saw
blade. Use only blades whose permissible maxi-
mum speed is not lower than the maximum spindle
speed of the circular saw and of the material to
be cut.
After you have switched off the motor, never slow
down the saw blade by applying pressure to its
side.
Only t blades which are well sharpened and have
no cracks or deformations.
Only use saw blades that are recommended by the
manufacturer, comply with EN 847-1.
Faulty saw blades must be replaced immediately.
Never use saw blades which do not comply with
the data specied in this manual.
Never dismantle the machines safety devices or
render them inoperative.
If the table insert is worn, replace it.
Always stand to the side of the saw blade when
working with the saw.
Never load the machine so much that it cuts out.
Make sure that off-cuts do not catch on the saw
blade crown.
Never remove loose splinters, chips or jammed
pieces of wood when the saw blade is running.
To rectify faults or remove jammed pieces of wood,
always switch off the machine rst. - Unplug the
power plug -
If the sawing gap is worn, replace the table insert.
Turn off the machine and unplug the power plug.
Carry out retooling work, adjustments, measure-
ments and cleaning jobs only when the motor is
switched off. - Unplug the power plug -
Before switching on, make sure that all keys and
wrenches have been removed from the tool.
Switch off the motor and unplug the power plug
before you leave the workplace
Ret all guards and safety devices immediately
after you have completed any repairs or mainte-
nance work.
Be sure to observe the safety information and op-
erating and maintenance instructions issued by the
manufacturer, as well as the dimensions listed in
the Technical Data.
It is imperative to observe the accident prevention
regulations in force in your area as well as all other
generally recognized rules of safety.
Make sure you stand squarely and keep your bal-
ance at all times.
Check the tool for damage!
Each time before re-using the tool, carefully check
that the guards or any slightly damaged parts are
working as intended.
Check that the moving parts are in good working
order, that they do not jam, and that no parts are
damaged. Make sure that all parts are tted cor-
rectly and that all other operating conditions are
properly fullled.
Unless otherwise stated in the operating instruc-
tions, damaged safety devices and parts must be re-
paired or replaced by an authorized service center.
This tool conforms to the applicable safety regula-
tions. Repairs may only be performed by a special-
ist using original spare parts. Otherwise accidents
could occur.
If necessary, wear suitable personal protection
equipment. This could consist of:
- Ear plugs to prevent the risk of damaging your
hearing;
- A breathing mask to avoid the risk of inhaling
hazardous dust.
- Always wear gloves when handling saw blades
and rough materials. Whenever practicable, saw
blades must be carried in a container.
The operator must be informed about the condi-
tions that inuence the generation of noise (for
example saw blades designed to reduce noise
emissions, caring for blades and the machine).
Faults on the machine or its guards, safety devices
and blade must be reported to the person in charge
as soon as they are discovered.
Use only the transport devices to move the ma-
chine. Never use the guards for handling and mov-
ing the machine.
All operators must receive proper training in the
use, adjustment and operation of the machine.
Do not saw any materials that contain foreign bod-
ies such as wires, cables or ties.
Only use sharp saw blades.
Warning! This electric tool generates an electromag-
netic eld during operation. This eld can impair active
or passive medical implants under certain conditions.
In order to prevent the risk of serious or deadly injuries,
we recommend that persons with medical implants
consult with their physician and the manufacturer of
the medical implant prior to operating the electric tool.
3. Use only as authorized
The rewood circular saw is designed exclusively
with the offered tool for the processing of wood.
The machine corresponds to the valid EC guide-
line.
The log saw is constructed as 1-man-operating
stand and is only to be used in outdoor locations.
The log saw is a portable circular saw. It is only ap-
plicable to cross cut rewood with a feeding rocker
according to the technical specications.
The saw is constructed solely for cross cutting of
rewood with max. 1 meter length.
Regardless of the diameter of the wood only 1
work piece is to be put on the rocker.
Observe all safety and hazard notes on the ma-
chine and ensure they are kept complete and in a
legible condition.
Observe all safety and hazard notes on the ma-
chine and ensure they are kept complete and in a
legible condition.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach Wox D 700 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach Wox D 700 in the language / languages: English, German, French as an attachment in your email.

The manual is 3.19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Scheppach Wox D 700

Scheppach Wox D 700 User Manual - English, German, Dutch, French, Italian, Swedish, Spanish - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info