782523
19
Zoom out
Zoom in
Previous page
1/76
Next page
15
Insert cutting of larger work pieces, Fig. L
Work step:
Remove splitting wedge and upper machine cover. Attach
set cutting attachment to parallel stop. Adjust back kick
block with the work piece receiver and the check block.
Put work piece against the back kick block, evenly lodge
and feed up to the check block and retract in a safe posi-
tion. After insert cutting: Promptly reinstall the wedge and
the upper cover.
Servicing
Pay attention to the safety instructions on page GB8.
m Turn off the motor and pull the plug before ser-
vicing
or cleaning the machine.
All protection and safety devices must be immediately as-
sembled again following repairs and servicing.
1. The assemblage of the circular saw is largely service-
free, including the electric motor. Exceptions to this are
the normal wear and tear of the saw blades as well as
the bench insert. If needed, exchange the used bench
insert.
2. The bench surface should always be kept resin-free.
3. Keep the saw blade protection box free of wood and
chip residue. When the power plug is pulled, open the
protection box cover and remove any saw dust obstruc-
tions.
5. The motor brake is maintenance-free and will function
for at least 5000 switch operations. If the after-running
time exceeds ten seconds, please inform the manufac-
turer.
Belt change – Belt tension fig. 18 / 19
Attention! Pull the mains plug out.
1 Dismount protective cover (A).
Loosen the 9 cross-head screws, turn round the swing
gate at 45° using the hand wheel (B) and remove the
protective cover.
2 By loosening both hex nuts (C), you slack the drive
belt.
3 Now you can take off the drive belt from the front and
after that from the back belt pulley.
Mount the new driving belt in reverse order.
Pay attention, it should be laid out on the complete belt
pulley surface.
4 Then stretch the drive belt, tighten both hex nuts (C)
and remount the protective cover (A) on the housing.
Due to a low belt tension a loss of power is possible. Check
the belt tension and fix the problem by stretching the drive
belt.
Follow the procedure as mentioned in chapter 1, 2 and 4.
Electrical connection
The installed electric motor is completely wired ready for
operation.
The customer’s connection to the power supply system, and
any extension cables that may be used, must conform with
local regulations.
Motor braking unit
The scheppach Tisa 5.0 circular saw bench is fitted with an
automatic motor braking unit which becomes effective as
soon as the driving motor is switched off.
Important remark:
The electric motor is designed for the S 6 / 40 % operating
mode.
Therefore, the motor is automatically switched off in the
event of an overload. The motor can be switched on again
after a cooling down period that can vary.
m Defective electrical
connection cables
Electrical connection cables often suffer insulation dam-
age.
Possible causes are:
1. Pinch points when connection cables are run through
window or door gaps.
2. Kinks resulting from incorrect attachment or laying of
the connection cable.
3. Cuts resulting from running over the connecting cable.
4. Insulation damage resulting from forcefully pulling out
of the wall socket.
5. Cracks through aging of insulation.
Such defective electrical connection cables must not be
used as the insulation damage makes them extremely haz-
ardous.
Check electrical connection cables regularly for damage.
Make sure the cable is disconnected from the mains when
checking.
Electrical connection cables must comply with the regula-
tions applicable in your country.
Single-phase motor
1. The mains voltage must coincide with the voltage speci-
fied on the motor’s rating plate.
2. Extension cables up to a length of 25-m must have a
cross-section of 1.5 mm2, and beyond 25 m at least
2.5 mm2.
3. The connection to the mains must be protected with a
16 A slow-acting fuse.
Three-phase motor
1. The mains voltage must coincide with the voltage speci-
fied on the motor’s rating plate.
2. The mains connection and the extension cable must
have 5 conductors: 3 phase conductors + 1 neutral con-
ductor + 1 earth conductor.
3. The extension cable must have a minimum cable cross-
section of 1.5 mm2.
4. The connection to the mains must be protected with a
16 A slow-acting fuse.
5. The rotating direction must be checked when the
machine is connected to the mains or re-sited. If
necessary, the polarity will have to be changed over
(wall socket).
Only a qualified electrician is permitted to connect the ma-
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach Tisa 5.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach Tisa 5.0 in the language / languages: English, German, Dutch, Danish, French, Swedish, Finnish as an attachment in your email.

The manual is 3.22 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info