Electrical connection
The electrical motor installed is connected and ready
for operation. The connection complies with the ap-
plicable VDE and DIN provisions.
The customer‘s mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
Passage points, where connection cables are
passed through windows or doors.
Kinks where the connection cable has been im-
properly fastened or routed.
Places where the connection cables have been cut
due to being driven over.
Insulation damage due to being ripped out of the
wall outlet.
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H07RN“.
The printing of the type designation on the connec-
tion cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of 16A (C) or 16A (K) for machines with a high
starting current (starting from 3000 watts)!
10. Cleaning
 󰀨       
switch of the device prior to carrying out mainte-
nance or repair work on the plasma cutter.
Regularly clean the outside of the plasma cutter
and its accessories. Use compressed air, cotton
waste or a brush to remove dirt and dust.
In case of a defect or a necessary replacement of
equipment parts, please contact the appropriate

11. Transport
󰀨
Lift the plasma cutter using the carrying handle (1).
In order to release the compressed air hose (19),
you must press the locking mechanism of the com-
pressed air connection (19a) and pull out the com-
pressed air hose (19) at the same time.
        
regulator.
m IMPORTANT!
You must fully assemble the appliance before using it

m ATTENTION!

        
󰀨

    -
-
ating personnel.
9. Initial operation
1. Set the plasma cutter up in a dry and well venti-
lated area.
2. Position the machine in the vicinity of the work-
piece.
3. 󰀨
4. Clamp the ground terminal (5) to the workpiece to
be cut and make sure that there is a good electri-
cal contact.
5. Set the cutting current on the current controller
(12). If the arc beam is interrupted the cutting cur-
rent must be set higher if necessary. If the elec-
trode burns through frequently, then the cutting
current must be set lower.
6. To cut in the manual cutting mode, pull the over-
lying burner across the workpiece while maintain-
ing a constant speed. To achieve the perfect cut,
it is important for the material thickness to com-
ply with the correct cutting speed. If the cutting
speed is too low, the cutting edge will be blunt
due to the severe heat input. The optimal cutting

inclined towards the rear while cutting. If the plas-

󰀨
-
der to cool the burner. The same process is fol-
lowed when the workpiece is pulled out with a
pressed plasma burner button (14). During the

󰀨
(13) as a result of overheating.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach PLC40 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach PLC40 in the language / languages: English, German, French, Polish as an attachment in your email.

The manual is 4.15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info