- Keep the splitting knife guides clean.
(dirt, splinters, bark, etc.)
- Lubricate slide bars with spray oil or grease
Check oil level of hydraulics
Check hydraulic connections and screws
for tightness and abrasive wear. If neces-
sary retighten the screw connections.
When do I change the oil?
First oil change after 50 operating hours, then
always after 250 operating hours.
Check the oil level.
Check the oil level frequently before each start-
up. If the oil level is too low, the oil pump may be
damaged.
Note: The oil level must be checked while the
splitting knife is retracted. The oil dipstick is
located on the splitting column in the ller plug
A (Fig. 5) und is provided with 1 slot. If the
oil level is at the lower end of the dipstick, this
indicates that the minimum oil level has been
reached. If this is the case, the oil must be
relled immediately. The slot indicates the maxi-
mum oil level.
The oil tank is situated in the splitting column
and is lled with high-quality hydraulic oil by the
manufacturer.
Change of the hydraulic oil and the oil lter.
Place a container under the suction hose.
Remove the hose clamp of the pump and pull off
the suction hose. Caution: allow the oil to ow
into the container! Fig. 7
Remove the suction hose completely and by
slightly tilting, allow the remaining oil to drain
into the container.
To change or clean the lter, remove the entire
intake manifold by means of a at spanner
SW41 or pipe wrench! Fig. 7.1
Clean the lter and re-mount with new sealing
tape, item no.: 1607 0333. Connect the suction
hose again and secure with hose clamps.
Remove the ller plug and ll with new hydraulic
oil.
Attention! Make sure that no dirt particles
enter the oil tank.
Dispose of used oil accordingly by taking it
to the local waste oil collection points. It is
prohibited to drain used oil into the soil or to
mix it with waste.
We recommend the following hydraulic oils:
Q8 Haydn 46
Aral Vitam gf 22
BP Energol HLP-HM 22
Mobil DTE 11
Shell Tellus 22
or equivalent.
Do not use other oil grades! The use of other
oil types affects the function of the hydraulic
cylinder.
Only when operated by PTO: change the oil of
the transmission gearing after the rst 35 opera-
ting hours, then after 1,000 operating hours or at
least once per year. Ensure that the connections
of the hydraulic system do not leak.
Hydraulic system
The hydraulic system is a closed system with oil
tank, oil pump and control valve.
The factory-made and completed system must
not be modied or re-engineered.
Check the oil level frequently.
Too low an oil level may damage the oil pump.
Check the hydraulic connections and screws for
tightness frequently – retighten if necessary.
Prior to maintenance and checking procedures,
clean the work space and have appropriate tools
in good condition to hand.
The above-indicated time intervals refer to
normal terms of use; if the machine is exposed
to heavy load, those time intervals decrease
accordingly.
Clean the machine casing, the panels and the
control levers with a soft, dry cloth that you can
moisten a little with a neutral cleaning agent.
Do not use alcohol or benzene since they might
damage the surfaces.
Keep oil and lubrication grease out of the reach
of unauthorised personnel. Read the instruc-
tions on the containers carefully and observe
them strictly. Avoid skin contact and rinse well
after use.
Troubleshooting
In cases of errors not mentioned below, please contact the customer service of the company scheppach.
Error Possible causes Solution Degree of danger
The hydraulic pump does
not run
No voltage Check whether the conductors
have power supply
Danger of an electric shock
This work process must be
performed by a maintenance
electrician.
The thermo-switch of the motor has
turned itself off.
The thermo switch turns on again
when the motor has cooled down.
The motor can be re-started.
The column does not
move downwards
Low oil level Check the oil level and rell Danger of contamination!
This work process can be carried
out by the machine operator.
2-manual shift not correct Check the xing of the levers Risk of being cut!
Dirt in the column guide Clean the column
Motor starts but the
column does not move
downwards
Incorrect rotating direction of the
motor during three-phase current
Check rotating direction of the
motor and shift to correct direction
Incorrect rotating direction can
damage the pump
Maintenance and repairs
All maintenance procedures must be performed
by qualied personnel under strict observation of
the available operating manual.
Prior to each maintenance, all possible
precautions must be taken; turn off the motor
and disconnect the power supply (if necessary,
unplug the power plug). Place a sign on the
machine which explains the outage of the device
“Machine out of service due to maintenance:
unauthorized persons are not allowed to start up
the machine or to remain in close proxim.
23
DGB
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach OX 7-1020 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach OX 7-1020 in the language / languages: English, German, French as an attachment in your email.

The manual is 3.51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info