7. Before starting the equipment
Before you connect the equipment to the mains supply
make sure that the data on the rating plate are identical
to the mains data.
Check the equipment for damage which may have
occurred in transit. Report any damage immediately
to the transport company which was used to deliver
the compressor.
Install the compressor near the point of consumption.
Avoid long air lines and supply lines (extension ca-
bles).
Make sure that the intake air is dry and dustfree.
Do not install the compressor in a damp or wet room.
The compressor may only be used in suitable rooms
(with good ventilation and an ambient temperature
from +5 °C to 40 °C). There must be no dust, acids,
vapors, explosive gases or inammable gases in the
room.
The compressor is designed to be used in dry rooms.
It is prohibited to use the compressor in areas where
work is conducted with sprayed water.
The oil level in the compressor pump has to be
checked before putting the equipment into operation.
8. Attachment and operation
m Important!
You must fully assemble the appliance before using it
for the rst time!
You will require the following tools for assembly and in-
stallation: 2 x open-ended wrench size 19 mm (not in-
cluded)
You will require the following tools for assembly and in-
stallation: 2 x open-ended wrench size 14 mm (not in-
cluded)
8.1 Fitting the wheels (Fig. 5)
Fit the supplied wheels (11) as shown.
8.2 Fitting the supporting foot (2x)(Fig. 6)
Fit the supplied supporting foot (2x) as shown.
8.3 Fitting the air lter (2x)(Fig. 7,8)
Remove the transportation stop (A) and screw the air
lter (14) to the equipment.
8.4 Changing the transportation cover (B) (Fig. 9,10)
Remove the transportation cover from the oil lter
opening (19) and insert the supplied oil sealing plug
(15) into the oil ller opening.
8.5 Mains connection
The compressor is equipped with a mains cable with
shock-proof plug. This can be connected to any 230-
240V ~ 50 Hz shock-proof socket.
Before you use the machine, make sure that the
mains voltage is the same as the operating voltage
(see the rating plate).
Long supply cables, extensions, cable reels etc.
cause a drop in voltage and can impede motor start-
up.
At low temperatures below +5°C, sluggishness may
make starting difcult or impossible.
8.6 ON/OFF switch (Fig. 2)
Pull the ON/OFF switch (16) upwards to switch on the
compressor. To switch off the compressor, press the
ON/OFF switch down.
8.7 Setting the pressure (Fig. 1,3)
Use the pressure regulator (5) to set the pressure on
the pressure gauge (4).
The set pressure can be drawn from the quick lock
coupling (3).
The vessel pressure can be read off the pressure
gauge (6).
The vessel pressure is drawn from the quick lock cou-
pling (7).
8.8 Setting the pressure switch (Fig. 1)
The pressure switch (2) is set at the factory. Cut-in
pressure approx. 6 bar Cut-out pressure approx. 8
bar.
8.9 Overload switch (Fig. 14)
The motor is tted with an overload switch (18). If the
compressor overloads, the overload switch switches off
the equipment automatically to protect the compressor
from overheating. If the overload switch triggers, switch
off the compressor using the ON/ OFF switch (16) and
wait until the compressor cools down. Then press the
overload switch (18) and restart the compressor.
9. Electrical connection
The electrical motor installed is connected and ready for
operation. The connection complies with the applicable
VDE and DIN provisions.
The customer‘s mains connection as well as the exten-
sion cable used must also comply with these regula-
tions.
The product meets the requirements of EN 61000-
3-11 and is subject to special connection condi-
tions. This means that use of the product at any
freely selectable connection point is not allowed.
Given unfavourable conditions in the power supply
the product can cause the voltage to uctuate tem-
porarily.
The product is intended solely for use at connection
points that
a) do not exceed a maximum permitted supply im-
pedance “Z” (Zmax = 0.382 Ω), or
b) have a continuous current-carrying capacity of
the mains of at least 100 A per phase.
As the user, you are required to ensure, in consulta-
tion with your electric power company if necessary,
that the connection point at which you wish to oper-
ate the product meets one of the two requirements,
a) or b), named above.
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach HC52dc at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach HC52dc in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Swedish, Finnish as an attachment in your email.

The manual is 5,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info