9. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions. The
customer‘s mains connection as well as the ex-
tension cable used must also comply with these
regulations.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
Passage points, where connection cables are
passed through windows or doors.
Kinks where the connection cable has been im-
properly fastened or routed.
Places where the connection cables have been cut
due to being driven over.
Insulation damage due to being ripped out of the
wall outlet.
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H05VV-F“.
The printing of the type designation on the connec-
tion cable is mandatory.
AC motor
The mains voltage must be 230 V~
Extension cables up to 25 m long must have a
cross-section of 1.5 mm².
Connections and repairs of electrical equipment
may only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
Type of current for the motor
Machine data - type plate
Machine data - type plate
10. Cleaning, maintenance, storage
and transport
m Important!
Pull out the power plug before doing any cleaning
and maintenance work on the equipment. Risk of
injury from electric shock!
m Important!
Wait until the equipment has cooled down com-
pletely! Risk of burns!
m Important!
Always depressurize the equipment before car-
rying out any cleaning and maintenance work!
Risk of injury!
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor in
areas where work is conducted with sprayed water.
8. Attachment and operation
m Important!
You must fully assemble the appliance before
using it for the rst time!
You will require the following tools for assembly
and installation:
2 x open-ended wrench size 14 mm (not included)
8.1 Fitting the wheels (g. 6,7)
Screw on each wheel (3) one washer (C) and one
nut (B) on to the threads of the wheels.
Then mount the wheels (3) on the wheel holders,
at the bottom of the pressure vessel (2), by using
a wrench to x the nut (B), washer (C) and ange
nuts (D) on the other side of the thread.
8.2 Fitting the supporting foot (g. 5)
Mount the enclosed supporting foot (4) with the
two hex bolts (A), the two washers (C) and two
ange nuts (D), as shown in Figure 5.
8.4 Mains connection
The compressor is equipped with a mains cable
with shock-proof plug. This can be connected to
any 230V~ / 50 Hz shock-proof socket which is
protected by a 16 A fuse.
Before you use the machine, make sure that the
mains voltage is the same as the operating voltage
(see the rating plate).
Long supply cables, extensions, cable reels etc.
cause a drop in voltage and can impede motor
start-up.
At low temperatures below +5 °C, sluggishness
may make starting difcult or impossible.
8.5 ON/OFF switch (g. 2)
To switch on the compressor, press the button (8)
on position I.
To switch off the compressor, press the button (8)
on position 0.
8.6 Setting the pressure (g. 2)
You can adjust the pressure on the pressure gauge
(6) using the pressure regulator (7).
The set pressure can be taken from the quick lock
coupling (5).
8.7 Setting the pressure switch
The pressure switch is set at the factory.
Cut-in pressure approx. 8 bar.
Cut-out pressure approx. 10 bar.
72


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach HC51V at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach HC51V in the language / languages: English, German, French, Italian, Polish as an attachment in your email.

The manual is 4.55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info