www.schaerer.comProduct description
Operating instructions / V07 / 06.2010
43 / 68
Power supply
Model Power rating
Fuse (installa-
tion site)
Siena
Siena 2
220-230V~ 50/60 Hz 2000-2200 W 10-16A
200V~ 50/60 Hz
2200W 10-16A
240V~ 50/60 Hz
100V~ 50/60 Hz
1200W 16A
110V~ 50/60 Hz
120V~ 50/60 Hz
130V~ 50/60 Hz
The device must be electrically connected according to all valid regulations (VDE 0100) as well as national
stipulations. The type of power cable must be at least H 05 VV-F. The voltage specied on the serial plate
must match the supply voltage at the installation location.
The phase must be protected from short-circuits with the Ampere value mentioned on the serial
plate!
All poles of the device must be able to be disconnected from the power supply.
Never operate a device with a faulty power cord. Have a defective power cord or plug replaced
immediately by a qualied service technician.
Schaerer Ltd. advises against the use of extension cables! • If an extension cable must be used,
nevertheless (minimum cross-section: 1.5 mm2), please observe the cable manufacturers data
(instructions for use) and all local regulations.
Power cords must be connected in such a way that no one can trip over them. Do not pull the
cords over corners or sharp edges, pinch them between objects or allow them to hang loosely
in a room.
Do not place cables over hot objects, and protect them from oil and aggressive cleaning
agents. Never lift or pull the device by its power cord. Never pull the plug out of the socket
by its cord. Never touch the power cord or plug with wet hands! Never insert a wet plug into a
power socket!
Water connection / draining (option)
The water supply connection must be made in accordance with the applicable requirements and the regu-
lations of the respective country.
If the machine is connected to a newly installed water pipe, the pipe and the supply tube must be thor-
oughly rinsed so that no dirt particles can enter the machine. The coffee maker must be connected to an
installed drinking-water pipe with shutoff valve. The machine is installed by using the mounted pressure
tube and the G 1/4“ screw at the pressure relief component mounted to the tap (set to 0.2 MPa (2 bar)). If
the machine is attached to a water drainage system, the supplied temperatureresistant drain hose must
be connected to the drip pan and siphon. It must be rmly attached to the drain and slanted at a downward
angle (so that the water can ow downward).
Always use the new hose set (fresh water/outlet hose) provided with the machine!
The ideal hardness of the water is 5 6 °dH (German hardness) or 8 10 °fH (French hardness). The
chlorine content should not exceed 100 mg per litre. Ideal Ph value = 7. Otherwise, the local regulations
are binding
Water pressure
Recommended: 0.1-0.3 MPa (1-3 bar)
Maximum: 0.6 MPa (6 bar)
Water ingress temperature
Minimum: 5 °C
Maximum: 30 °C
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Schaerer Siena 2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Schaerer Siena 2 in the language / languages: English as an attachment in your email.

The manual is 17,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Schaerer Siena 2

Schaerer Siena 2 User Manual - German - 34 pages

Schaerer Siena 2 User Manual - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info