V03 | 08.2012
17
www.schaerer.comInstallation and commissioning
Water connection/draining
Conditions
CAUTION!
Risk of machine
damage!
The machine can suffer damage due to bad material and wrong water values.
It is imperative that the following points are complied with:
The water must be free of contaminants and the chlorine content must not exceed 100 mg
per litre.
Do not connect the machine to pure reverse osmosis water or other aggressive types of
water.
The carbonate hardness must not exceed 5 – 6°dKH (German carbonate hardness) or 8
– 10°fKH (French carbonate hardness) and the total hardness value must always be great-
er than the carbonate hardness.
The minimum carbonate hardness is 4°dKH or 7°fKH. The pH value must be between 6.5
and 7
Always use the new hose set (fresh water/waste water hose) provided with the machine.
The water supply connection must be made in accordance with the applicable requirements
and the regulations of the respective country. If the machine is connected to a newly installed
water pipe, the pipe and infeed hose must be rinsed well to ensure that no dirt gets into the
machine.
The coffee machine must be connected to an installed drinking water line with a shut-off valve.
Installation takes place via the installed pressure hose and the 3/8”-threaded union piece onto
the pressure reducer that is mounted on the water tap (set to 0.3 MPa (3 bar)).
If the machine is connected to a drain, the included temperature-resistant drain hose must be
connected to the drip tray and the siphon. It must be firmly attached to the drain and slanted
at a downward angle (so that the water can flow downward).
Power requirements
Installation
Unpacking the machine
Unpack the machine.
Check the remaining package contents for accessories.
Remove the accessories supplied in the grounds container and water tank.
Keep the original packaging in case the equipment needs to be sent back.
Automatic commissioning program
Connect the coffee machine to the mains power supply.
Switch on the coffee machine.
The commissioning program automatically starts the first time the machine is switched
on. It explains all aspects of installation.
Water pressure
Recommended: 0.1 – 0.6 MPa (1-6 bar)
Maximum: 0.6 MPa (6 bar)
Water inlet temperature
Minimum: 10°C
Maximum: 35°C
Read the “Setting up the coffee machine” and “Power supply” chapters carefully before install-
ing.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Schaerer Coffee Prime at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Schaerer Coffee Prime in the language / languages: English as an attachment in your email.

The manual is 4,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Schaerer Coffee Prime

Schaerer Coffee Prime User Manual - German - 64 pages

Schaerer Coffee Prime Installation Guide - Dutch - 2 pages

Schaerer Coffee Prime User Manual - Dutch - 46 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info