Primary air
The primary air regulation mechanism is used for lighting the fire, or
to boost the burning process when you put wood on. The primary air
vent can be 0-50% open if you use hard wood fuel such as oak and
beech. You can close the primary air vent if you use soft wood such
as birch or pine for fuel.
Settings for normal load: 0 - 50%
Secondary air
Secondary air is pre-heated and fed indirectly to the fire. At the same
time, the secondary airflow cleans the glass pane to avoid soot build-
up. If you over-restrict the secondary airflow, soot can build up on the
glass pane. The secondary airflow determines the heat output from
your wood stove.
Settings for normal load: 40 - 70%
Ash drawer
Open the glass door to access the ash drawer which is located below
the combustion chamber.
Keep the ash drawer closed at all times when the wood stove is lit.
The ash drawer must not be overfilled and must therefore be emp-
tied at regular intervals.
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\DSA 12\90085005.idw
90085005
Brændkammer, spjæld og askeskuffe
09-06-2011
BC
Scan DSA 12
VÆGT:
AREAL:
N/A
N/A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg
©
TG.NR:EMNE:
C:\Working Folder\Designs\DSA 12\90085005.idw
90085005
Brændkammer, spjæld og askeskuffe
09-06-2011
BC
Scan DSA 12
VÆGT:
AREAL:
N/A
N/A
CB-technique (Clean Burning)
The stove is equipped with the clean burning technique. In order to
ensure an optimal combustion of released gases under the incinera-
tion process, air will pass through a specially developed canal system.
The heated air is led into the combustion chamber through the small
holes at the rear of the burn chamber.
This air volume is controlled by the combustion rate and thus cannot
be regulated.
NOTE: The wood must never be placed higher than the tertiary holes
at the rear of the burn chamber (This does not apply at a cold start).
Lower baffle plate
The baffle plate is placed in the upper part of the combustion
chamber. This plate will block the smoke and give it a longer holding
time in the combustion chamber before it goes up the chimney. The
temperature of the flue gases will decrease because it has more time
to release heat from the stove. When sweeping, remove the smoke
deflector plate and read the "Stove maintenance" section. Be aware
that the baffle plates are made from a porous chemical material
which can break easily. You must therefore take care when handling
them. The baffle plates are wearing components and do not entail a
right to claim.
Lower baffle plate
Secondary air
0% - 100%
Adjustment of air supply,
primary and secondary damper
A
NAVN:
STI:
DIMENSION:
MATERIALE:
DATO:
SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
I:\Udvikling\TEGNING\DSA 12\90085007.idw
90085007
Primær og sekundær luftregulering
21-01-10
BC
Scan DSA 12
VÆGT:
AREAL:
N/A
N/A
Pin supporting the
baffle plate
CB Technique
Primary air
Ash drawer
14
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scan DSA 12 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scan DSA 12 in the language / languages: English as an attachment in your email.

The manual is 2,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Scan DSA 12

Scan DSA 12 User Manual - German - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info