INSTRUCTIONS FOR USE
CB-TECHNOLOGY (CLEAN BURN)
The stove is equipped with CB technology. In order to ensure optimal combustion of gases released during the combustion
process, air passes through a specially developed system of channels. The heated air is conducted into the combustion chamber
through the holes in the rear lining of the combustion chamber and at the baffle plates. This airflow is controlled by the rate of
combustion and cannot therefore be regulated.
NOTE: The wood must never be placed higher than the tertiary holes at the rear of the burn chamber (This does not apply at a
cold start).
PRIMARY AIR
The primary air is used when lighting the stove and must be closed after 10-20 minutes, when the fire has caught well. The prima-
ry air can be used continuously when using very hard wood.
Settings for normal load: 0 - 30%
SECONDARY AIR
Secondary air is pre-heated and fed indirectly to the fire. At the same time, the secondary airflow cleans the glass pane to avoid
soot build-up. If you over-restrict the secondary airflow, soot can build up on the glass pane. The secondary airflow determines
the heat output from your wood stove.
Settings for normal load: 50 - 70%
BAFFLE PLATES
The baffle plates are located in the upper part of the combustion chamber. The plates hold back smoke, making sure it stays
inside the combustion chamber for a longer time before escaping through the chimney. This reduces the flue gas temperature as
the gases have more time to dissipate heat to the stove.
The baffle plates must be removed for sweeping; see “Maintenance”. Note that the baffle plates are made of porous, ceramic
material, and is liable to break easily. You should therefore handle them with care.
The baffle plates are subject to wear and tear and not covered by the warranty.
ASH CONTAINER
¬ Open the door of the stove to access the ash container under the combustion chamber
¬ The ash container must always be closed during operation
¬ The ash container must not be become too full and must therefore be emptied at regular intervals
¬ Never empty ashes into a flammable container. Ashes can contain glowing embers long after you finish operating the stove
REFUELING ON TO A LOW FIRE BED
If there is insufficient burning material in the fire bed to light a new fuel charge, excessive smoke emission can occur. Refueling
must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in a reasonable
period. If there are too few embers in the fire bed, add suitable kindling to prevent excessive smoke.
Ash container in closed position
Ash container in open position
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scan 83 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scan 83 in the language / languages: English as an attachment in your email.

The manual is 7,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Scan 83

Scan 83 User Manual - German - 40 pages

Scan 83 User Manual - Dutch - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info