TECHNICAL DATA AND DIMENSIONS
Materials
Steel plate
Cast iron
Galvanised sheet
Vermicolite
Surface treatment Senotherm
Max. wood length ca. 33 cm
Weight Scan 68-1/2/7/8 ca. 98 kg
Weight Scan 68-3/4/9/10 ca. 105 kg
Weight Scan 68-5/6/11/12 ca. 107 kg
Weight Scan 68-13/14 ca. 110 kg
Weight Scan 68-13/14 LB ca. 100 kg
Weight Scan 68-15/16 ca. 190 kg
Weight Scan 68-15/16 LB ca. 170 kg
Connecting piece internal diameter 144 mm
Connecting piece external diameter 148 mm
Approval type Intermittent fuelling*
Intermittent operation in this context means normal use
of a wood-burning stove. In other words, you should let
the fire die down until only the embers are left before
refueling.
This stove is produced in accordance with type approval
for the product, which also covers the product’s Assembly
and Instruction Manual.
The Declaration of Performance (DoP) is available from
www.scan.dk
*
Test in compliance with EN 13240
CO Emission at 13% O20,04 %
CO Emission at 13% O2556 mg/Nm3
Dust @ 13% O214 mg/Nm3
Nox @ 13% O285 mg/Nm3
Efficiency 80 %
Energy efficiency index 107
Energy efficiency class A+
Nominel output 5,5 kW
Chimney temperature EN 13240 265 °C
Amount of smoke 5,3 g/sek
Sub-pressure EN 13240 12 Pa
Recommended sub-pressure in
connecting piece 17 Pa
Required combustion air supply 16,2 m3/h
Fuel Wood
Fuel consumption 1,6 kg/h
Amount of fuel 1,4 kg
Test in compliance with EN 13240
in smoke restricted areas
CO Emission at 13% O20,06 %
CO Emission at 13% O2785 mg/Nm3
Dust @ 13% O212 mg/Nm3
Nox @ 13% O291 mg/Nm3
Efficiency 79 %
Energy efficiency index 105,6
Energy efficiency class A
Nominel output 5 kW
Chimney temperature EN 13240 248 °C
TECHNICAL DATA
INSTALLATION
¬ The house owner is responsible for ensuring that installation and assembly are in accordance with national and local
building regulations as well as the information provided in this Assembly and Instructions Manual.
¬ When you install any kind of fireplace or stove, you must inform the local building and housing authorities. In addition
you are obliged to have the installation inspected and approved by a local chimney sweep prior to commissioning.
¬ To ensure best-possible functionality and safety for your installation, we advise you to call a professional fitter. Your Scan
dealer will be able to recommend a qualified fitter in your area. For information on Scan Dealers, please go to www.scan.dk.
SAFETY
Any changes made to the product by the dealer, fitter or user could result in the product and safety functions not functioning as
intended. The same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case
if parts that are necessary for the operation and safety of the stove are dismantled or removed.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scan 68 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scan 68 in the language / languages: English as an attachment in your email.

The manual is 11,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Scan 68

Scan 68 User Manual - German - 48 pages

Scan 68 User Manual - Dutch - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info