745585
10
Zoom out
Zoom in
Previous page
1/40
Next page
NAVN:
STI:
DIMENSION:
MATERIALE: DATO: SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5004\95004002.idw
95004002
Opstillingsafstand m. varmeskjold
16-11-2017 sr
Scan 5004
VÆGT:
AREAL:
N/A
N/A
267 mm
400 mm
300 mm
Min. 500 cm2
Min. 750 cm2
A-A ( 1 : 10 )
A A
NAVN:
STI:
DIMENSION:
MATERIALE: DATO: SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:
EMNE:
C:\Working Folder\Designs\Scan 5004\95004003.idw
95004003
Opstillingsafstand m. varmeskjold
sr
Scan 5004
VÆGT:
AREAL:
N/A
N/A
100 mm
25 mm
500 mm*
300 mm*
Alle mål er minimusmål.
Møbleringsafstand: 800 mm til rude
Brandbart materiale
Brandmur F.eks. 50 mm Jøtul firewall, 110 mm mursten eller
andet materiale med tilsvarende brandfasthed og isolationsevne.
* Afstand til glas
NAVN:
STI:
DIMENSION:
MATERIALE: DATO: SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 5004\95004092.idw
95004092
Opstillingsafstand m. varmeskjold Scan 5004 FRL
05-10-2018 sr
Scan 5004 FRL
VÆGT:
AREAL:
N/A
N/A
267 mm
800 mm
400 mm
**
NAVN:
STI:
DIMENSION:
MATERIALE: DATO: SIGN:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
TG.NR:EMNE:
C:\Working Folder\Designs\Scan 1005\91005029.idw
91005029
Uisoleret røgrør
23-01-2019 KEN
Scan 1005
VÆGT:
AREAL:
N/A
N/A
175
100
75
15
450
200
1500
800
10
Installation with an insulated, vertical flue pipe
- structure/surround to ceiling
BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL
Building in the Scan 5004 FRL with radiation shields against a flammable wall protected by a fire wall.
Lower
convection
opening
Upper
convection
opening
Floor
Ceiling
Flammable material
Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick
or other material with corresponding fireproof and
insulating abilities
All distances are in mm.
All distances are minimum distances
Distance to furniture: 800 mm. from glass
* Distance to glass
** Distance to flammable floor
Insulated length
Ceiling
Installation with an insulated, vertical flue pipe
- open structure/surround
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scan 5004 FRL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scan 5004 FRL in the language / languages: English as an attachment in your email.

The manual is 4,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Scan 5004 FRL

Scan 5004 FRL User Manual - German - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info