745583
5
Zoom out
Zoom in
Previous page
1/36
Next page
5
TECHNICAL DATA AND DIMENSIONS
Test in compliance with EN 13229
CO Emission at 13% O
2
0,08
%
CO
Emission at 13% O
2
940
mg/Nm
3
Dust @ 13% O
2
11
mg/Nm
3
No
x
@ 13% O
2
118
mg/Nm
3
Efficiency
85
%
Energy efficiency index
114,3
Energy efficiency class
A+
Nominel output
5,7
kW
Chimney temperature EN 13229
206
°C
Temperature in flue conn. piece
246
°C
Amount of smoke
4,4
g/sek
Sub-pressure EN 13229
12
Pa
Recommended sub-pressure in
connecting piece
16-20 Pa
Required combustion air supply
10-25
m
3
/h
Fuel
Wood
Fuel consumption 2 kg/h
Amount of fuel required to light 2 kg
Amount of fuel, max. 2,5 kg
Materials
Steel plate
Cast iron
Galvanised sheet
Chamotte
Surface treatment Senotherm
Max. log length 45 cm
Weight Scan 5003 FR/FL 115 kg
Weight Scan 5003 FR/FL
w/heat shield
128 kg
Flue conn. piece internal diameter 132 mm
Flue conn. piece external diameter 149 mm
Approval type Intermittend*
* Intermittent operation in this context means normal use of
a built-in stove. In other words, you should let the fire die
down until only the embers are left before refuelling.
This built-in stove is produced in accordance with type
approval for the product, which also covers the product’s
Assembly and Instruction Manual.
The Declaration of Performance (DoP) is available from
www.scan.dk
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scan 5003 FR-FL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scan 5003 FR-FL in the language / languages: English as an attachment in your email.

The manual is 3,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Scan 5003 FR-FL

Scan 5003 FR-FL User Manual - German - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info