CONVECTION AIR
The covering must contain holes for convection air. Convection means that there is an air circulation ensuring that the
heat is equally distributed in the room. It is important the demands concerning convection areas are observed.
¬ Min. area for ingoing convection air: 500 cm2 ¬ Min. area for outgoing convection air: 750 cm2
If there is not enough convection air, the covering may be damaged. Convection air grids are available as an accessory.
EXISTING CHIMNEY AND PRE-FABRICATED ELEMENT CHIMNEY
If you intend to connect your stove to an existing chimney, it makes sense to contact an authorised Scan dealer, or a local
chimney sweep, for advice. These experts will also let you know if your chimney needs renovating.
¬ When connecting a pre-fabricated element chimney, follow the manufacturer’s connection instructions for the
relevant chimney type.
CONNECTION BETWEEN BUILT-IN STOVE AND STEEL CHIMNEY
Your Scan dealer, or local chimney sweep, can advise you on choosing a make and type of steel chimney. This ensures that
the chimney will match your wood-burning stove. As a general rule, the length of the chimney should not be less than 3.5
metres, measured from the top of the built-in stove. Specific weather or installation conditions might require a different
length.
¬ Choosing the wrong length or diameter of steel chimney could impair functionality.
¬ Always comply exactly with the instructions provided by the steel chimney supplier.
REQUIREMENTS FOR CHIMNEY
The chimney must have a minimum internal diameter of 148 mm and have a T400 designation, with G for the soot fire test.
If you opt to connect the stove with an elbow pipe, you should use a curved elbow, as this gives a better draught.
If you connect the stove with a sharp elbow pipe, the cleansing lid must be placed in the vertical part so that the
horizontal part can be cleaned through here.
The requirements to the chimney and the flue pipe in terms of safety distances must be met.
BALANCED FLUE
If the stove is connected with a balanced flue, we recommend the use of a 100 mm Lindab tube and a chimney length of
min. 4.5 m.
BUILDING IN THE STOVE IN FLAMMAMABLE MATERIALS
The stove is NOT to be built into flammable materials without the use of a fire wall and heat shields!
BUILDING IN THE STOVE AT A FIRE WALL
We refer to the building sketches on page 11.
POSITIONING THE STOVE AT NON-FLAMMABLE MATERIALS
When bricking up/constructing a non-combustible covering, the distance to the stove must be min. 10 mm.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scan 5001 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scan 5001 in the language / languages: English as an attachment in your email.

The manual is 3,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Scan 5001

Scan 5001 User Manual - German - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info