745580
11
Zoom out
Zoom in
Previous page
1/36
Next page
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 80\90580001.idw
90580001
Opstillingsafstand, hjørne, Scan 1008
03-03-2017
sr
Scan 80
Weight:
Area:
N/A N/A
3
5
0
m
m
25 mm
2
5
m
m
Møbleringsafstand: 800 mm.
Brandbart materiale
Brandmur
F.eks. 50 mm. Jøtul firewall
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 80\90580003.idw
90580003
Opstillingsafstand, hjørne, Scan 1008
04-12-2018
ken
Scan 1008
Weight:
Area:
N/A N/A
Loft
Gulv
Møbleringsafstand: 800 mm.
Brandbart materiale
Brandmur
F.eks. 50 mm. Jøtul firewall
M
i
n
.
3
0
0
m
m
M
i
n
3
5
0
m
m
Min. 300 cm² konvektion
1
0
0
0
m
m
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 80\90580077.idw
90580077
Opstillingsafstand, hjørne, Scan 1008
05-12-2018
ken
Scan 1008
Weight:
Area:
N/A N/A
Loft
Gulv
Møbleringsafstand: 800 mm.
Brandbart materiale
Brandmur
F.eks. 50 mm. Jøtul firewall
Min. 300 cm² konvektion
Min. 500 cm² konvektion
7
0
0
m
m
3
5
0
m
m
M
i
n
.
3
0
0
m
m
**
**
Stove:
Path:
Articlenumber:
Material:
Date:
Constructed/Changed by:
SCAN A/S
DK-5492 Vissenbjerg©
Drawing
number:
Name:
C:\Working Folder\Designs\Scan 80\90580002.idw
90580002
Opstillingsafstand, hjørne, Scan 1008
05-12-2018
ken
Scan 1008
Weight:
Area:
N/A N/A
Loft
Gulv
Møbleringsafstand: 800 mm.
Brandbart materiale
Brandmur
F.eks. 50 mm. Jøtul firewall
Min. 300 cm² konvektion
Min. 500 cm² konvektion
7
0
0
m
m
3
5
0
m
m
M
i
n
.
3
0
0
m
m
3
8
0
m
m
Min. 300 cm
2
Min. 500 cm
2
Min. 300 cm
2
Min. 500 cm
2
11
BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL
Flammable material
Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick
or other material with corresponding fireproof and
insulating abilities
All distances are in mm.
All distances are minimum distances
Distance to furniture: 800 mm. from glass
** Distance to flammable floor
Installation with an insulated, vertical flue pipe
- open structure/surround
Installation with an insulated, vertical flue pipe
- structure/surround to ceiling
The distance to fire wall (brick) depends on the use of
an insulated flue pipe all the way down to the insert
- SCAN 1008
Installation with an un-insulated elbow pipe
Cavities are not to
be filled out with
insulation material!
Lower
convection
opening
Upper
convection
opening
Lower
convection
opening
Upper
convection
opening
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scan 1008 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scan 1008 in the language / languages: English as an attachment in your email.

The manual is 6,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Scan 1008

Scan 1008 User Manual - German - 36 pages

Scan 1008 User Manual - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info