699394
86
Zoom out
Zoom in
Previous page
1/110
Next page
84 VERSA Plus SATEL
Options – options related to SIA-IP format:
Send MAC address – if this option is enabled, the MAC address is sent with event code.
Send timestamp – if this option is enabled, the date and time are sent with event code
(the monitoring station can change the date and time in the control panel).
Encrypt data – if the option is enabled, the data being sent are encrypted, and the date
and time are sent with event code (the monitoring station can change the date and time
in the control panel).
SIA-IP key – the key to encrypt data to be sent using the SIA-IP format.
hex – if the option is enabled, you can enter up to 32 hexadecimal characters as the SIA-IP
KEY
. If the option is disabled, you can enter up to 16 alphanumeric characters as the
SIA-IP KEY.
SIA-IP acct – a string of up to 16 hexadecimal characters, which is used to identify the
control panel for the purpose of reporting in SIA-IP format.
Supervision interval – in the case of reporting in the SIA-IP format, an additional
transmission can be sent at specified intervals to check communication with the monitoring
station. You can program a number of days, hours, minutes and seconds between the
transmissions. Entering zeros only means that no additional transmission will be sent.
11.5 Event codes
For the pulse and Ademco Express formats, it is necessary to program codes which will be
reported to the monitoring station if the defined events occur. An event code consists of 2
hexadecimal characters (digits or letters from A to F). The reported events are those for
which a code different from “00” has been programmed.
For the Contact ID and SIA formats, event codes consistent with format specification are
sent. In case of the CONTACT ID (SELECTED) and SIA (SELECTED), the codes must be
programmed at the events which are to be reported (not the programmed code, but a code
consistent with the format specification will be sent).
11.6 Starting the reporting
1. Get the data necessary to properly start the reporting from the monitoring station
operator:
depending on the transmission path:
telephone number of the monitoring station (reporting via analog telephone line,
CSD reporting, SMS reporting, reporting via GSM voice channel),
server address, TCP port number, S
TATION KEY and ETHM/GPRS KEY (reporting via
Ethernet network and GPRS reporting),
SMS message format (SMS reporting),
transmission format required by the monitoring station,
identifiers assigned to the alarm system,
list of event codes (not applicable to Contact ID and SIA formats).
2. Determine whether the event codes will be sent to both monitoring stations or to one of
them only (enable one of the options: STATION 1 OR 2, STATION 1, STATION 2, STATION 1
AND
2 or STATION 1 OR 2 (DUAL PATH REPORTING)).
3. Determine whether the number of events from the same source is to be limited (EVENTS
AMOUNT LIMITING
option).
4. Determine when the restore code is to be sent (R
ESTORE AFTER BELL, RESTORE AFTER
DISARM
options).
86


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Versa Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Versa Plus in the language / languages: English as an attachment in your email.

The manual is 2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Versa Plus

Satel Versa Plus User Manual - English - 44 pages

Satel Versa Plus Installation Guide - English - 36 pages

Satel Versa Plus Quick start guide - English - 11 pages

Satel Versa Plus Installation Guide - English - 32 pages

Satel Versa Plus Quick start guide - German - 12 pages

Satel Versa Plus Additional guide - German - 113 pages

Satel Versa Plus User Manual - German - 46 pages

Satel Versa Plus Installation Guide - German - 36 pages

Satel Versa Plus Quick start guide - Dutch - 11 pages

Satel Versa Plus User Manual - Dutch - 46 pages

Satel Versa Plus Additional guide - Dutch - 110 pages

Satel Versa Plus Additional guide - Dutch - 2 pages

Satel Versa Plus Installation Guide - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info