699394
75
Zoom out
Zoom in
Previous page
1/110
Next page
SATEL VERSA Plus 73
The zones in the system to which the wireless sirens are assigned can be programmed as:
NC, NO or EOL – provides information about troubles (a trouble causes the zone
violation),
2EOL/NC or 2EOL/NO – provides information about troubles (a trouble causes the zone
violation) and about tamper.
The type of zones to which the wireless siren is assigned should be matched to the
information sent:
ASP-100 – first zone: low battery; second zone: tamper.
ASP-105 – first zone: low battery and tamper; second zone: external 12 V DC power loss
and tamper.
ASP-205 – both zones: low battery and tamper.
The tamper information is sent immediately, while the trouble information:
ASP-100 – during periodical transmission, which is sent every 15 minutes,
ASP-105 / ASP-205 – during polling.
Tamper alarm on opening the tamper switch in the siren:
ASP-100 – lasts for the maximum duration of signaling programmed for the siren (sound type
selected during programming and optical signaling);
ASP-105 – lasts for the maximum duration of acoustic signaling programmed for the siren
(sound type selected during programming and optical signaling);
ASP-205 – lasts 3 minutes (sound type 1 and optical signaling).
Tamper signaling is blocked:
when the control panel is running in service mode,
when the ABAX system is running in test mode (ASP-105 and ASP-205),
for 10 minutes after connecting the battery (ASP-100),
for 40 seconds after power-on (ASP-105) / installing the battery (ASP-205).
It enables installation work to be carried out. Opening the tamper switch will not trigger
loud signaling, but information on tamper will be sent (when in service mode, the
control panel will not signal the tamper alarms). The command to block/unblock the
signaling connected with starting / ending the test mode or the service mode is sent
during the response time.
Wireless expanders of hardwired zones and outputs
The wireless expander of hardwired zones and outputs (ACX-200 or ACX-201) takes up 4
zones and 4 outputs in the system. The alarm system zone / output to which the zone /
output in ACX-200 or ACX-201 expander is assigned is programmed in the same way as the
other hardwired zones / outputs of the control panel. You should remember however that
sensitivity of the expander zones may be different from that programmed in the control panel:
from 20 ms to 140 ms – the same as the value programmed in the control panel,
above 140 ms – only some values are available: 300 ms, 500 ms, 700 ms, etc. every
200 ms (the programmed value is rounded up to that supported by the expander).
The EN50131-3 standard requires that zones must react to signals lasting more than
400 ms. It means in case of the wireless expanders of hardwired zones and outputs
that no values exceeding 300 ms should be entered when programming the sensitivity
(the higher the value, the lower the sensitivity).
The expander informs you about the zone status as it changes. Also the expander outputs
are controlled in real time. Only the programming of zones takes place during the response
75


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Versa Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Versa Plus in the language / languages: English as an attachment in your email.

The manual is 2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Versa Plus

Satel Versa Plus User Manual - English - 44 pages

Satel Versa Plus Installation Guide - English - 36 pages

Satel Versa Plus Quick start guide - English - 11 pages

Satel Versa Plus Installation Guide - English - 32 pages

Satel Versa Plus Quick start guide - German - 12 pages

Satel Versa Plus Additional guide - German - 113 pages

Satel Versa Plus User Manual - German - 46 pages

Satel Versa Plus Installation Guide - German - 36 pages

Satel Versa Plus Quick start guide - Dutch - 11 pages

Satel Versa Plus User Manual - Dutch - 46 pages

Satel Versa Plus Additional guide - Dutch - 110 pages

Satel Versa Plus Additional guide - Dutch - 2 pages

Satel Versa Plus Installation Guide - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info