56 VERSA Plus SATEL
Alarm 3 incorrect codes (mobile application) [Al.3 wrong codes] – if this option is enabled,
entering an invalid code three times from the VERSA CONTROL application will trigger an
alarm.
Push notifications – if this option is enabled, the VERSA CONTROL application can provide
information about alarm system events by means of push notifications.
MAC – information on module hardware address.
ID – information on individual identification number for the purpose of communication via the
SATEL server (programming by means of DLOADX program, operating by means of
VERSA CONTROL application). The ID number is assigned automatically by the SATEL
server.
If the control panel is to be used in another alarm system, the hitherto used ID number
must be deleted. It can be done from the keypad, when programming the built-in
communication modules, in the last step, if the control panel is connected to the
SATEL server. Having deleted the old ID number, the control panel will receive a new
one. The VERSA CONTROL applications using the old ID number will be unable to
connect to the control panel.
IP – information on the module local / public address.
QR-code – pressing the button will display the “QR-code” window. The window shows the
QR code containing information required when configuring settings of the VERSA
CONTROL application. You can read the QR code by using a mobile device or export to
file and transmit to the users. The QR code facilitates configuring the VERSA CONTROL
application settings.
Refresh – pressing the button will update information presented in the MAC, ID and IP fields.
Time from a time server
LAN (LAN) [Time from srvLAN] – if the option is enabled, the control panel clock will be
synchronized with the time server once a day through the Ethernet module.
For communication with the time server, the DNS server must be used.
GSM [Time from srvGSM] – if the option is enabled, the control panel clock will be
synchronized with the time server once a day through the GSM module (GPRS).
If the LAN and GSM options are enabled at the same time, time synchronization via
the Ethernet module has priority. Time synchronization by means of the GSM module
will take place only if an attempt to synchronize time via the Ethernet module fails.
Time from GSM network [Time from GSMnet] – if the option is enabled, the control panel
clock is synchronized with the time of GSM network operator.
Synchronizing the clock with the GSM network time has the top priority. Only if
synchronization with the GSM network time fails will the clock be synchronized with
the time server.
Time zone – difference between the universal time (GMT) and the zone time. The parameter
is required, if the control panel clock is to be synchronized.
9.2.1 Ethernet communication module (ETHM)
ETHM (LAN) [Use ETHM] – if the option is enabled, the built-in module is supported by the
control panel. The option should be disabled, if the module is not to be used. Disabling the
option will prevent the unnecessary reporting of troubles related to this module.
58


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Versa Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Versa Plus in the language / languages: English as an attachment in your email.

The manual is 2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Versa Plus

Satel Versa Plus User Manual - English - 44 pages

Satel Versa Plus Installation Guide - English - 36 pages

Satel Versa Plus Quick start guide - English - 11 pages

Satel Versa Plus Installation Guide - English - 32 pages

Satel Versa Plus Quick start guide - German - 12 pages

Satel Versa Plus Additional guide - German - 113 pages

Satel Versa Plus User Manual - German - 46 pages

Satel Versa Plus Installation Guide - German - 36 pages

Satel Versa Plus Quick start guide - Dutch - 11 pages

Satel Versa Plus User Manual - Dutch - 46 pages

Satel Versa Plus Additional guide - Dutch - 110 pages

Satel Versa Plus Additional guide - Dutch - 2 pages

Satel Versa Plus Installation Guide - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info