3.18 Output control
Using the keypad, you can control the operation of devices connected to the outputs (e.g. to
raise/lower roller blinds/shutters, turn on/off lighting or heating, etc.). The installer defines
how the outputs should work (whether the output will be activated for a defined time, or it will
remain active until deactivated by the user, timer, etc.).
3.18.1 Quick control of outputs
The installer can assign outputs to the numeric keys and allow them to be quickly controlled
(without entering the code).
Quick activation of output
Press the key to which the controllable output is assigned, and then .
Quick deactivation of output
Press the key to which the controllable output is assigned, and then .
3.18.2 Controlling the outputs by means of function
Enter the user menu and press in turn . The status of outputs is illustrated by
LEDs designated by numbers. The steady-on LEDs indicate which outputs are activated. The
blinking LED indicates that that the cursor is there. Use the and key to move the
cursor. The cursor can only be moved over the LEDs presenting the status of outputs that
can be controlled. Press to activate the output with the number corresponding to that of
the LED, or press to deactivate the output.
3.19 Tests
3.19.1 Zone test
The function enables checking the system zones and detectors connected to them for proper
functioning.
You can test the zones for which the installer has programmed other wiring type than
NOT USED.
Zone violation during the test will not trigger the control panel reaction, as
preprogrammed for the zone.
When testing the zones, the keypad does not present the current zone state, but only
indicates whether or not the zone was violated during the test.
1. Enter the user menu and press in turn .
2. Enter two digits to define the test duration (e.g. if the time is to be 5 minutes, press in turn
and – the test may last from 1 to 15 minutes), and then press . The
LEDs designated by the numbers of zones you can test will start blinking.
3. Violate the selected zones (e.g. walking through the area supervised by the motion
detector or opening the window supervised by the magnetic contact). The keypad should
inform you that the zone has been violated (the LED designated by the zone number will
go on steady). Information on the violation will be presented until the zone test is
terminated.
4. The test will be terminated automatically after the defined time has elapsed. You can
terminate it earlier by pressing .
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Versa IP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Versa IP in the language / languages: English as an attachment in your email.

The manual is 0,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Versa IP

Satel Versa IP Quick start guide - English - 11 pages

Satel Versa IP Installation Guide - English - 36 pages

Satel Versa IP User Manual - English - 43 pages

Satel Versa IP Additional guide - English - 93 pages

Satel Versa IP Quick start guide - German - 11 pages

Satel Versa IP Additional guide - German - 97 pages

Satel Versa IP User Manual - German - 45 pages

Satel Versa IP Installation Guide - German - 38 pages

Satel Versa IP Quick start guide - Dutch - 2 pages

Satel Versa IP User Manual - Dutch - 45 pages

Satel Versa IP Quick start guide - Dutch - 12 pages

Satel Versa IP Additional guide - Dutch - 93 pages

Satel Versa IP User Manual - Dutch - 45 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info