68 VERSA SATEL
9.2 Timer parameters
Name – individual timer name (up to 16 characters).
Weekly schedule – the time of starting/ending timer for each day of the week and everyday
(the timer can be started/ended twice a day: according to the settings scheduled for the
given day of the week and according to the everyday settings).
Exception – the period during which the timer will be started/ended at a different time than
indicated in the weekly schedule. 4 exceptions can be programmed for a timer. You can
program for each exception:
the date from which the exception will apply,
the date to which the exception will apply,
the timer start/end time when an exception applies.
Partition arming mode – the arming mode that will be activated in the partition when the
timer will start.
10. Reporting
The control panel can send event codes to the monitoring station by using the following
transmission paths:
analog telephone line [built-in analog telephone communicator],
Ethernet network [requires the ETHM-1 / ETHM-1 Plus module to be connected].
If both transmission paths are used, the control panel will first try to send the event code
through the Ethernet network, and only when the attempt fails, it will switch over to the
telephone reporting.
10.1 Configuring the reporting
You can configure the reporting parameters and options:
DLOADX program: “VERSA – Reporting” window.
functions available in the M
ONITORING submenu (SERVICE MODE 5. MONITORING).
All parameters and options of reporting can only be configured by means of the
DLOADX program.
10.2 Reporting parameters and options
REPORTING TELEPHONE and REPORTING ETHM options are described in the “Global
options” section (p. 27).
10.2.1 Options
Station 1 or 2 – select this option if the control panel is to send event codes to Station 1, and
in the case of failure – to Station 2.
Station 1 – select this option if the control panel is to send event codes to Station 1 only.
Station 2 – select this option if the control panel is to send event codes to Station 2 only.
Station 1 and 2 – select this option if the control panel is to send event codes to both
monitoring stations.
Events amount limiting – if the option is enabled, events from the same source are saved
into the event log and reported to the monitoring station 3 times only. This option does not
apply to the alarms from zones (see: A
UTO-RESET 3 or AUTO-RESET 1 zone option).
70


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel VERSA 15 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel VERSA 15 in the language / languages: English as an attachment in your email.

The manual is 1,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel VERSA 15

Satel VERSA 15 Quick start guide - English - 11 pages

Satel VERSA 15 Installation Guide - English - 36 pages

Satel VERSA 15 User Manual - English - 32 pages

Satel VERSA 15 User Manual - English - 42 pages

Satel VERSA 15 Additional guide - German - 11 pages

Satel VERSA 15 User Manual - German - 44 pages

Satel VERSA 15 Installation Guide - German - 37 pages

Satel VERSA 15 Quick start guide - German - 2 pages

Satel VERSA 15 Quick start guide - Dutch - 11 pages

Satel VERSA 15 User Manual - Dutch - 44 pages

Satel VERSA 15 Quick start guide - Dutch - 2 pages

Satel VERSA 15 Additional guide - Dutch - 86 pages

Satel VERSA 15 Installation Guide - Dutch - 35 pages

Satel VERSA 15 Quick start guide - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info