5. 24H BURGLARY – dedicated zone for the detectors which should be armed at all times (e.g.
glass break detectors).
6. 24H TAMPER – dedicated, permanently armed zone for tamper circuits. Violation of the zone
is additionally signaled as a trouble.
7. 24H PANIC – permanently armed zone, intended for operating the panic buttons.
8. 24H PANIC SILENT – permanently armed zone, intended for operating the panic buttons.
Alarm from the zone is not signaled on keypads, proximity card arm/disarm devices and
outputs, but the event code is sent to the monitoring station.
9. 24H MEDICAL – permanently armed zone for calling medical assistance.
10. 24H FIRE – dedicated, permanently armed zone for operating fire detectors.
11. DETECTOR MASK – permanently armed zone for antimasking control. Violation of the zone
is interpreted by the control panel as a detector trouble.
12. NO ALARM ACTION – the zone may be used to control the output with function 13. ZONE
VIOLATION
, 15. CONTROLLED or 16. READY STATUS. An additional option enables the zone
to be used for supervision of the key box (KEYBOX CONTROL option).
13. ARM/DISARM the zone controls the arming status of the partition it belongs to. Violation of
the zone starts the arming procedure or disarms the partition (depending on the current
status of the partition).
14. ARMING – violation of the zone starts the procedure of arming the partition to which the
zone belongs.
15. DISARMING – violation of the zone disarms the partition to which the zone belongs.
16. EXIT DELAY TERMINATOR – violation of the zone ends the partition exit delay countdown.
17. SHUNT LOCK – the zone ends the partition exit delay countdown and – depending on the
BLOCKS VERIFICATION option – will disable verification or disarm the partition to which it
belongs. The way of controlling (the zone violation / zone restore) is determined by the
option RESTORE DISABLES VERIF. or RESTORE DISARMS.
18. ENTRY ROUTE ENABLING – violation of the zone activates delay for the 2. ENTRY/EXIT ROUTE
type zones in the partition to which the zone belongs. The zones will act as delayed ones for
the D
ELAY ACTIVATION TIME. After expiry of the time, unless the system is disarmed, the
zones will again act as the instant ones. If the DELAY ACTIVATION TIME for a zone will be
programmed as equal to 0, and at the same time the E
NTRY DELAY programmed for the
partition is equal to 0, violation of the zone will have no effect.
19. TROUBLE – violation of the zone is treated by the control panel as a trouble. Additionally,
an alarm event may be written into the control panel memory (see: E
VENT parameter).
6.5 Zone options
Alarm on exit delay end – when the option is enabled, if the zone is violated at the
moment of ending the exit delay countdown, it will trigger an alarm (if this option is
disabled, the zone will only trigger the alarm when the status changes from normal
to violation during the armed mode).
Priority – if the option is enabled, arming is impossible when the zone is violated.
Bypass disabled – if the option is enabled, the user cannot bypass the zone.
Active in night arm – if the option is enabled, the zone is armed when the night armed mode
is activated.
Active in day arm – if the option is enabled, the zone is armed when the day armed mode is
activated.
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel VERSA 15 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel VERSA 15 in the language / languages: English as an attachment in your email.

The manual is 1,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel VERSA 15

Satel VERSA 15 Quick start guide - English - 11 pages

Satel VERSA 15 Installation Guide - English - 36 pages

Satel VERSA 15 User Manual - English - 32 pages

Satel VERSA 15 User Manual - English - 42 pages

Satel VERSA 15 Additional guide - German - 11 pages

Satel VERSA 15 User Manual - German - 44 pages

Satel VERSA 15 Installation Guide - German - 37 pages

Satel VERSA 15 Quick start guide - German - 2 pages

Satel VERSA 15 Quick start guide - Dutch - 11 pages

Satel VERSA 15 User Manual - Dutch - 44 pages

Satel VERSA 15 Quick start guide - Dutch - 2 pages

Satel VERSA 15 Additional guide - Dutch - 86 pages

Satel VERSA 15 Installation Guide - Dutch - 35 pages

Satel VERSA 15 Quick start guide - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info