Filter [1272.Filter] – time counted from the moment of receiving a transmission from the
detector. After it has elapsed and no other transmission is received, trouble will be
reported.
6.3.1 Wireless detectors and zone settings
Depending on the settings of the zone to which a wireless detector is assigned:
NC, NO or EOL – the zone gives information about detector violation,
2EOL/NC or 2EOL/NO – the zone gives information about detector violation and tamper.
The information on tamper and tamper restore is sent by the detector in real time.
How information about violation is sent depends on the detector operating mode:
normal – the detector sends information on violation and violation restore in real time (the
zone status corresponds to the detector status),
energy save (available in some detectors) – after sending information on violation, the
detector will not send any further information about violations for 3 minutes (the zone will
be violated for 2 seconds after the controller receives the transmission containing
information on detector violation).
7. Outputs
The system supports the following outputs:
hardwired – on the control panel PCB and in the expander.
wireless – in the PERFECTA 32-WRL LTE control panel. There are 4 outputs that support
wireless sirens.
7.1 Output functions
0. N
OT USED
1. E
XTERNAL SIREN
– output activated by triggering burglary, panic or fire alarm. In the event
of the fire alarm, the output is pulsating.
2. I
NTERNAL SIREN
– output activated by triggering burglary, panic, fire or warning alarm. In the
event of the fire alarm, the output is pulsating.
3. B
URGLARY
– output activated after alarm is triggered by the 0. E
NTRY
/E
XIT
, 1. E
NTRY
/E
XIT
FINAL
, 2. I
NTERNAL
, 3. I
NSTANT
, 4. D
OUBLE KNOCK
or 5. 24
H
B
URGLARY
zone.
4. F
IRE ALARM
– output activated by triggering fire alarm from keypad or by the 10. 24
H
F
IRE
zone.
5. DURESS
ALARM
– output activated by using a code with D
URESS
right.
6. P
ANIC ALARM
– output activated by triggering panic alarm from keypad (loud or silent), by
the 7. 24
H
P
ANIC
or 8. 24
H
P
ANIC SILENT
zone.
7. MEDICAL
ALARM
– output activated by calling medical help from keypad or by the 9. 24
M
EDICAL
zone.
8. A
LARM
NOT VERIFIED
– output activated by triggering unverified alarm.
9. A
LARM
-
VERIFIED
– output activated by triggering verified alarm.
10. T
AMPER ALARM
– output activated by triggering tamper alarm.
11. F
IRE DETECTORS POWER SUPPLY
– output for power supply of fire detectors with automatic
alarm verification. The output is deactivated for 16 seconds after violation of the 10. 24
H
F
IRE
zone. If, after reactivation of the output, the zone will be violated again, fire alarm will
be triggered.
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel PERFECTA 32 LTE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel PERFECTA 32 LTE in the language / languages: English as an attachment in your email.

The manual is 0,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel PERFECTA 32 LTE

Satel PERFECTA 32 LTE Quick start guide - English - 10 pages

Satel PERFECTA 32 LTE User Manual - English - 30 pages

Satel PERFECTA 32 LTE Additional guide - English - 50 pages

Satel PERFECTA 32 LTE Installation Guide - English - 26 pages

Satel PERFECTA 32 LTE User Manual - German - 11 pages

Satel PERFECTA 32 LTE Additional guide - German - 50 pages

Satel PERFECTA 32 LTE Installation Guide - German - 27 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info