18 PERFECTA LTE SATEL
auto [Auto MCC/MNC] – if this option is enabled and the control panel cannot log into the
cellular network of operator defined by means of the MCC/MNC code, it will log into the
available cellular network.
Fig. 9. “GSM phone” tab.
Lock time [63.Block SIM1 / 65.Block SIM2] – the time during which switch-over to the other
SIM card is impossible. The time is counted from the moment of switch-over to the given
card. For reporting, the transmission paths programmed as subsequent ones, if they
require switch-over to the other card, will be skipped during the lock time countdown.
Entering the value 0 means that instant switch-over to the other SIM card is possible.
Return time [64.Restore SIM1 / 66.Restore SIM2] – the time after which the other SIM card
is to be used. Entering the value 0 means that automatic switch-over to the other SIM card
will not take place.
If two SIM cards are to be used, one of them must be treated as the priority card. It is
recommended that return time equal to 0 be programmed for it.
SMS for sending USSD code [111.USSD SIM1 / 112.USSD SIM2] – control command that
will be sent in the SMS message together with USSD code. The control panel will run the
USSD code and send the response received from the operator to the phone number from
which the SMS message with control command was sent. You can enter up to 8
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel PERFECTA 32 LTE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel PERFECTA 32 LTE in the language / languages: English as an attachment in your email.

The manual is 0,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel PERFECTA 32 LTE

Satel PERFECTA 32 LTE Quick start guide - English - 10 pages

Satel PERFECTA 32 LTE User Manual - English - 30 pages

Satel PERFECTA 32 LTE Additional guide - English - 50 pages

Satel PERFECTA 32 LTE Installation Guide - English - 26 pages

Satel PERFECTA 32 LTE User Manual - German - 11 pages

Satel PERFECTA 32 LTE Additional guide - German - 50 pages

Satel PERFECTA 32 LTE Installation Guide - German - 27 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info