6 PERFECTA LTE SATEL
included in the alarm system: control panel, keypads, detectors, sirens, expansion modules
etc. Thick walls, metal partitions, etc. decrease the range of cellular signal. Keep this in mind
when choosing the installation place for control panel. The control panel and other alarm
system components should be installed within the protected area.
6.2 Estimation of the system current consumption
At the security system planning stage you should sum up the currents consumed by all
devices included in the system (control panel mainboard, keypads, expansion modules,
detectors, sirens, etc.). The calculation should take into account the battery charging current.
If the sum of currents exceeds the maximum output current of the control panel power
supply, expander with power supply or an additional power supply unit should be used.
The sum of currents consumed by the devices connected to the power supply unit (expander
with power supply) must not exceed the power supply output current.
If you plan to connect devices to particular power outputs (of the control panel, expander with
power supply, etc.), remember that the sum of currents consumed by these devices must not
exceed the maximum current carrying capacity of those outputs.
6.3 Cabling
It is recommended that an unshielded non-twisted cable be used for making electric
connections between devices included in the system.
If you use the twisted-pair type of cable, remember that CLK (clock) and DTA (data)
signals must not be sent through one pair of twisted conductors.
Select cross-section of the power supply wires so that the supply voltage drop between the
power supply and the supplied device should not exceed 1 V as against the output voltage.
In order to guarantee correct functioning of the system components it is important that
resistance and capacitance of the signal wires be as low as possible. When the distances
between the devices are greater, several wires connected in parallel may have to be used for
each signal, in order to reduce conductor resistance. This, however, may lead in
consequence to an increase in conductor capacitance. Too high resistance or capacitance of
the cables connecting the control panel to keypads or expansion modules can prevent the
devices from working correctly (e.g. the control panel will be unable to identify devices,
absence of devices will be reported, etc.). When selecting the length of cables, follow
recommendations set out in sections on connection of particular types of devices.
Avoid running the cables in parallel to or in close vicinity of the 230 VAC wires, as this may
result in malfunctioning of the system.
6.4 Installation of control panel
The control panel mainboard contains electronic components sensitive to
electric charges.
Before connecting the mainboard to power supply source (battery, alternating
voltage from transformer), you must first complete all the installation work with
hardwired devices (connection of keypads, expansion modules, detectors etc.).
The control panel should be installed indoors, in spaces with normal humidity of air. The
control panel must be protected against unauthorized access. The installer should provide
protection for the users and service personnel by using a suitable device enclosure.
A 230 VAC power supply circuit with protective grounding must be available at the control
panel installation place.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel PERFECTA 32 LTE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel PERFECTA 32 LTE in the language / languages: English as an attachment in your email.

The manual is 0,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel PERFECTA 32 LTE

Satel PERFECTA 32 LTE Quick start guide - English - 10 pages

Satel PERFECTA 32 LTE User Manual - English - 30 pages

Satel PERFECTA 32 LTE Additional guide - English - 47 pages

Satel PERFECTA 32 LTE Additional guide - English - 50 pages

Satel PERFECTA 32 LTE User Manual - German - 11 pages

Satel PERFECTA 32 LTE Additional guide - German - 50 pages

Satel PERFECTA 32 LTE Installation Guide - German - 27 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info