SATEL PERFECTA 37
Encryption [SIA-IP encrypt.] – if the option is enabled, the data being sent are encrypted,
and the date and time are sent with event code (the monitoring station can program the
date and time in the control panel). Option for SIA-IP format.
Send date & time [Timestamp SIA-IP] – if the option is enabled, the date and time are sent
with event code (the monitoring station can program the date and time in the control
panel). Option for SIA-IP format. It is available, when the E
NCRYPTION
option is disabled.
SIA-IP test report period [744.SIA-IP test / 764.SIA-IP test] – in the case of reporting in the
SIA-IP format, an additional transmission can be sent at specified intervals to check
communication with the monitoring station. You can program a number of days, hours,
minutes and seconds between the transmissions. Entering zeros only means that no
additional transmission will be sent.
9.1.2 Test transmissions
The test transmission is sent using all transmission paths included in the list that
defines the order of using transmission paths (cf. R
EPORTING PRIORITY
parameter).
At [791.At] – if the test transmission is to be sent regularly at a specified time, you must
define every how many days and at what time. As for the number of days, 0 is interpreted
as 1 (test transmission will be sent every day).
When armed [793.Armed] – if the test transmission is to be sent at regular intervals when the
system is armed, define every how many days, hours and minutes.
When disarmed [792.Disarmed] – if the test transmission is to be sent at regular intervals
when the system is disarmed, define every how many days, hours and minutes.
Test transmissions regardless of events [Independ.test] – this option refers to the test
transmissions sent at regular intervals (see W
HEN ARMED
and W
HEN DISARMED
parameters).
If this option is enabled, the time is counted from the last test transmission. If the option is
disabled, the time is counted from the last transmission, irrespective of whether it was
a test transmission, or a code of another event was sent.
9.1.3 Events selection
If the CID
SELECTED CODES
or SIA
SELECTED CODES
reporting format is selected, define
which events are to be sent to the monitoring station.
10. Messaging
The control panel can send notifications about alarm system events by means of:
voice messages – the voice messages which are to be used for notification should be
saved to the control panel by using the PERFECTA S
OFT
program,
SMS messages – the content of SMS messages is automatically generated by the control
panel.
10.1 Parameters and options of the messaging
10.1.1 Phones
In the control panel, you can enter data of 8 telephones which will be notified of events in the
alarm system. At the same time, users of these phones can control the alarm system by
using SMS messages.
Name [88.Names] – individual name of the telephone number (up to 16 characters).
Telephone no. [81.Numbers] – the telephone number.
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel PERFECTA 16 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel PERFECTA 16 in the language / languages: English as an attachment in your email.

The manual is 0,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel PERFECTA 16

Satel PERFECTA 16 Quick start guide - English - 10 pages

Satel PERFECTA 16 User Manual - English - 31 pages

Satel PERFECTA 16 Additional guide - English - 50 pages

Satel PERFECTA 16 Installation Guide - English - 27 pages

Satel PERFECTA 16 User Manual - German - 32 pages

Satel PERFECTA 16 Additional guide - German - 52 pages

Satel PERFECTA 16 Additional guide - German - 50 pages

Satel PERFECTA 16 Installation Guide - German - 28 pages

Satel PERFECTA 16 Quick start guide - Dutch - 11 pages

Satel PERFECTA 16 User Manual - Dutch - 32 pages

Satel PERFECTA 16 Additional guide - Dutch - 52 pages

Satel PERFECTA 16 Additional guide - Dutch - 50 pages

Satel PERFECTA 16 Installation Guide - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info