22 PERFECTA SATEL
Silent PANIC [Silent panic] – if this option is enabled, the panic alarm triggered from the
keypad will be a silent one, i.e. the keypad will not indicate it, there will be no audible
signal, but the alarm will be reported to the monitoring station. The silent panic alarm is
useful when the control panel is sending events to the monitoring station, but unauthorized
persons should not be aware of the alarm being triggered. The option is available, if the
PANIC
ALARM
option is enabled.
4.3.2 Display and keys
Date/time format [210.ClockFormat] – mode of presentation of time and date on the display.
LCD backlight [26.LCDbacklight] – mode of keypad display backlighting.
Keypad backlight [27.KEYbacklight] – mode of keypad keys backlighting.
Backlighting of the display and keys on the wireless keypad works differently than that
on the wired keypad (see PRF-LCD-WRL keypad manual).
Auto backlight [29.Autolight] – if the backlight of display or keys goes on automatically, you
can define whether and what event will additionally turn on the backlighting:
Not present – backlighting will be turned on only by pressing any key.
Zone violation – backlighting will be turned on additionally in the event of zone violation
(select the zone).
Entry delay in part. – backlighting will be turned on additionally in the event of starting the
entry delay countdown in the partition (select the partition).
The A
UTO BACKLIGHT
parameter is not available for the wireless keypad.
4.3.3 Chime
The keypad can audibly signal violation of selected zones.
The wireless keypad signals the CHIME from zones not more frequently than once
every 30 seconds. In the inactive mode, the CHIME from zones is only signaled if
W
AKE
-
UP DURATION
is different from 0.
4.3.4 Volume
[251.Keys] – volume level of the beeps generated during keypad operation (key
pressing, confirmation of performed operation, etc.).
[252.Chime] – volume level of the beeps generated after zone violation (CHIME).
[253.Entry delay] – volume level of the entry delay beeps.
[254.Exit delay] – volume level of the exit delay beeps.
[255.Fire alarm] – volume level of the fire alarm beeps.
[256.Burg.alarm] – volume level when signaling burglary, panic and medical (auxiliary)
alarms.
[257.Warn.alarm] – volume level when signaling warning alarms.
[258.New trouble] – volume level when signaling troubles.
4.3.5 Wireless keypad PERFECTA 16-WRL / PERFECTA 32-WRL
For the wireless keypad, additional parameters and options are available.
Filter [1272.Filter] – the time counted from receiving of the transmission from the keypad.
After it has elapsed and no other transmission is received, trouble will be reported.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel PERFECTA 16-WRL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel PERFECTA 16-WRL in the language / languages: English as an attachment in your email.

The manual is 0,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel PERFECTA 16-WRL

Satel PERFECTA 16-WRL Quick start guide - English - 10 pages

Satel PERFECTA 16-WRL User Manual - English - 31 pages

Satel PERFECTA 16-WRL Additional guide - English - 50 pages

Satel PERFECTA 16-WRL Installation Guide - English - 27 pages

Satel PERFECTA 16-WRL Quick start guide - German - 11 pages

Satel PERFECTA 16-WRL User Manual - German - 32 pages

Satel PERFECTA 16-WRL Additional guide - German - 52 pages

Satel PERFECTA 16-WRL Additional guide - German - 50 pages

Satel PERFECTA 16-WRL Installation Guide - German - 28 pages

Satel PERFECTA 16-WRL Quick start guide - Dutch - 11 pages

Satel PERFECTA 16-WRL User Manual - Dutch - 32 pages

Satel PERFECTA 16-WRL Additional guide - Dutch - 52 pages

Satel PERFECTA 16-WRL Additional guide - Dutch - 50 pages

Satel PERFECTA 16-WRL Installation Guide - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info