699900
4
Zoom out
Zoom in
Previous page
1/4
Next page
4 MSD-350 SATEL
3. Remove the discharged battery.
4. Install a new CR123A 3 V lithium battery.
5. Close the detector enclosure.
6. Press and hold down the test/reset button (designated with the letter A in Figure 2). Alarm should be
triggered.
6. Specifications
Operating frequency band ...................................................................................................... 433.05 ÷ 434.79 MHz
Radio communication range (in open area) ...........................................................................................up to 200 m
Battery....................................................................................................................................................CR123A 3 V
Battery life expectancy..........................................................................................................................up to 3 years
Standby current consumption .......................................................................................................................... 85 µA
Maximum current consumption..................................................................................................................... 120 mA
Operating temperature range .................................................................................................................. 0°C...55°C
Dimensions .........................................................................................................................................ø108 x 54 mm
Weight...............................................................................................................................................................170 g
The MSD-350 wireless smoke detector conforms to the essential requirements of the EU Regulations and
Directives:
CPR 305/2011 Regulation of the European Parliament and of the Council of 9 March 2011 laying down
harmonized conditions for the marketing of construction products and repealing the Council Directive
89/106/EEC on construction products;
EMC 2014/30/EU Electromagnetic Compatibility Directive;
RED Directive 2014/53/EU of the European Parliament and of the Council of 16 April 2014 on the harmonization
of the laws of the Member States relating to the making available on the market of radio equipment and
repealing Directive 1999/5/WE.
The CNBOP-PIB Certification Body in Józefów issued the Certificate of Constancy of Performance 1438-CPR-
0623 for the construction product MSD-350 Wireless Smoke Detector, confirming its compliance with the
requirements of EN 14604:2006.
The CNBOP-PIB Certification Body in Józefów has tested the MSD-350 Wireless Smoke Detector confirming its
compliance with the EN 14604 Standard, within the scope of Appendix L (approved for the use in caravans and
camper vans).
The Certificate and the Declaration of Performance can be downloaded from the www.satel.eu. website
18
SATEL Sp. z o.o. • ul. Budowlanych 66 • 80-298 Gdańsk • POLAND
1438
1438-CPR-0623
MSD-350
EN 14604
Fire safety. MSD-350 Wireless Smoke Detector, stand-alone, capable of interacting over the air with the
intruder alarm system, based on scattered light principle, designed for indoor use.
Declaration of Performance 1438-CPR-0623
Application – fire safety.
Technical specifications – please refer to this manual.
SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gdańsk • POLAND
tel. +48 58 320 94 00
www.satel.eu
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel MSD-350 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel MSD-350 in the language / languages: English as an attachment in your email.

The manual is 0,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel MSD-350

Satel MSD-350 User Manual - German - 4 pages

Satel MSD-350 User Manual - Dutch - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info