699074
24
Zoom out
Zoom in
Previous page
1/35
Next page
22 Installer Manual SATEL
5.10.2 Backup power supply
A 12 V lead-acid sealed battery should be connected to the control panel as a backup power
source. The battery capacity must be adequately selected to match current consumption in
the system. According to EN 50131 Grade 3, the battery must ensure operation of the system
without mains supply for 30 hours, when the reporting is enabled in the control panel.
Do not connect deeply discharged battery to the control panel (with voltage
across unloaded terminals below 11 V). The battery should be precharged with
a proper charger.
The used batteries must not be discarded, but should be disposed of in
accordance with the existing rules for environment protection.
If the battery voltage drops below 11 V for longer than 12 minutes (3 battery tests), the
control panel will indicate battery failure. When the voltage goes down to approx. 10.5 V, the
battery will be disconnected.
5.10.3 Control panel power-up / start-up procedure
1. Deenergize the 230 V AC circuit to which the transformer is to be connected.
2. Connect the 230 V AC wires to the terminals of transformer primary winding.
3. Connect the terminals of transformer secondary winding to the AC terminals on control
panel electronics board.
4. Connect the battery to the dedicated leads (positive terminal to RED lead, negative
terminal to BLACK lead). The control panel will not start after connecting the battery
alone. Included in the control panel set are adapters (matching connectors) for
connection of battery with twisted cable ends, therefore the battery cable ends should not
be cut off.
5. Turn on 230 V AC power supply in the circuit to which the transformer is connected.
The control panel will start operating.
If you have any problems with starting the control panel, enter the service mode
from the pins and restore the factory default settings (see EMERGENCY
PROCEDURE OF THE CONTROL PANEL START-UP p. 23).
The above mentioned power-up sequence (first the battery, then the 230 V AC mains) will
ensure proper operation of the power supply unit and the electronic protection circuits, thus
preventing damage to the alarm system components caused by installation mistakes, if any.
If the control panel power supply has to be disconnected, disconnect the mains first
and then the battery. When reconnecting the power supply, observe the above
mentioned sequence.
5.11 First start-up of the control panel
After the first start-up of the control panel, it is advisable to restore the factory
default settings using the CLEAR ALL function ([SERVICE CODE] SERVICE MODE
RESTARTS CLEAR ALL), and then quit the service mode. When a prompt
appears on the keypad display, whether the data should be saved to the FLASH
memory, press the “1” key on the keypad.
The control panel with factory settings (a new one or one after restart of settings) supports all
keypads connected to the bus, irrespective of the addresses set in them. However, it does
not allow you to program the system. You will be able to start programming after carrying out
the following operations:
1. Setting individual, correct addresses in keypads (see p. 14).
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Integra 64 Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Integra 64 Plus in the language / languages: English as an attachment in your email.

The manual is 0,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Integra 64 Plus

Satel Integra 64 Plus User Manual - English - 51 pages

Satel Integra 64 Plus Additional guide - English - 102 pages

Satel Integra 64 Plus User Manual - German - 55 pages

Satel Integra 64 Plus Additional guide - German - 108 pages

Satel Integra 64 Plus Installation Guide - German - 36 pages

Satel Integra 64 Plus User Manual - Dutch - 53 pages

Satel Integra 64 Plus Additional guide - Dutch - 108 pages

Satel Integra 64 Plus Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info