699079
67
Zoom out
Zoom in
Previous page
1/114
Next page
SATEL INTEGRA 65
94. ALARM UNAUTHORIZED ACCESS similarly as type 93, but the signaling only applies to
modules with enabled ALARM ON UNAUTH. ACCESS option.
95. IP REPORTING TROUBLEsignals troubles related to reporting over Ethernet and by means
of GPRS.
96. TELEPHONE LINE TROUBLE informs about telephone communication troubles.
In the case of INTEGRA 128-WRL control panel, the output type 96 is called GSM
TROUBLES and indicates the GSM communication related troubles.
97. VOICE MESSAGE similarly as types 48-63, but the numbers of synthesizers (messages)
must be selected.
98. REMOTE SWITCH similarly as types 64-79, but the numbers of remote switches must be
selected.
99. ACCESS CARD READ signals read-in of the user card.
100. CARD HOLDDOWNsignals holding the user card.
101. CARD READEXPANDER signals that the card has been read in indicated
modules/keypads.
The 101. CARD READ EXPANDER type output may be used for execution of the access
control function from INT-KLCDR / INT-KLFR / INT-KWRL2 / INT-KWRL keypad. To
do so:
in the output settings, indicate the keypad on which reading in the card will activate
the output, and the partitions from which the users will be able to open the door,
in the keypad settings, assign the door opening function to presenting / holding the
card and indicate the 101. CARD READ EXPANDER type zone as the door to be
opened.
102. LINK TROUBLE WIRELESS ZONE signals lack of communication with wireless devices
assigned to the selected zones.
103. LINK TROUBLE WIRELESS OUTPUT signals lack of communication with wireless devices
assigned to the selected outputs.
104. WIRELESS DEVICE LOW BATTERY signals some problems with power supply of wireless
devices.
105. SHUTTER UP dedicated for raising the roll shutters. It becomes active after violation of
selected zones or disarming of selected partitions. It can also be triggered from the
keypad, by means of the user function OUTS CONTROL. The cut-off time programmed for
the output should be longer than that required for raising the roll shutters.
106. SHUTTER DOWN dedicated for lowering the roll shutters. It becomes active after
violation of selected zones or arming of selected partitions (upon starting the arming
procedure). It can also be triggered from the keypad, by means of the user function OUTS
CONTROL
. The cut-off time programmed for the output should be longer than that required
for lowering the roll shutters.
The roller shutter up and down functions must be assigned to consecutive
(following each other) physical outputs.
If the 105. SHUTTER UP and 106. SHUTTER DOWN type outputs are to be controlled from
the keypad, they must be assigned to a group of outputs (see: Output groupsp. 68).
For the 105. SHUTTER UP and 106. SHUTTER DOWN type outputs, indicate a partition so
that these outputs can be controlled from the keypad serving the given partition. If the
partition status is not to control the output status, enable the NOT CONTROLLED BY
ARMING option.
107. CARD ON READER A indicates the proximity card / DALLAS iButton read-in by the
expander reader A. It can also signal card reading in the LCD keypad.
67


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Integra 24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Integra 24 in the language / languages: English as an attachment in your email.

The manual is 1,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Integra 24

Satel Integra 24 User Manual - English - 51 pages

Satel Integra 24 Installation Guide - English - 36 pages

Satel Integra 24 Quick start guide - German - 2 pages

Satel Integra 24 User Manual - German - 54 pages

Satel Integra 24 Additional guide - German - 121 pages

Satel Integra 24 Installation Guide - German - 38 pages

Satel Integra 24 Quick start guide - Dutch - 24 pages

Satel Integra 24 User Manual - Dutch - 52 pages

Satel Integra 24 Additional guide - Dutch - 121 pages

Satel Integra 24 Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info