50 Programming SATEL
Audible alarm after verification [Bell on 2nd] if this option is enabled, the alarms from
zones with the PRE-ALARM or WITH VERIFICATION option enabled will only trigger loud alarm
signaling after verification. The unverified alarms will not trigger loud alarm signaling.
Partition timer
Partitions can be controlled with an additional timer, which can be programmed:
in the keypad, using the function available in the user menu ([code] OPTIONS
PROGRAMMING
PARTITION TIMERS),
in the DLOADX program connected to the control panel, in the Structure window,
Systemtab, after clicking on the partition name and then on the Partition timerbutton.
4.3 Zones
The zone is a separated portion of the protected area which can be supervised by a detector
or detectors. A zone can only be assigned to one partition.
The system supports the following zones:
hardwired on the control panel electronics board, in keypads and expanders.
The number of available hardwired zones is determined by the control panel during
identification procedure.
wireless in the INTEGRA 128-WRL control panel or after connecting the ABAX 2 /
ABAX wireless system controller. The number of available wireless zones depends on the
number of wireless devices registered in the system and is determined during the
procedure of adding the devices.
virtual zones which physically do not exist, but have been programmed as FOLLOW
OUTPUT
or are controlled by means of a keyfob.
4.3.1 Assigning zones to a partition
The zones can be assigned to a partition:
using the keypad, in the service mode, by means of the ZONES function (STRUCTURE
SYSTEM PARTITIONS SETTINGS [Part. Name] ZONES) see: Selection from the
multiple-choice listp. 26,
using the DLOADX program:
1. in the Structurewindow, Systemtab, after clicking on the partition name. Click on
the Add button to display the list of zones which can be assigned to the selected
partition. Click on the zone which is to be assigned to the partition.
2. in the Zoneswindow, Zonestab, Part.column, enter the number of partition to
which the given zone is to be assigned.
4.3.2 Programming the EOL resistor values
For the zones on INTEGRA 128-WRL control panel mainboard, some keypads and
expanders, the value of end-of-line resistors is programmable within the range from 500 to
15 k (the sum of preset values may not exceed 15 k).
The value of EOL resistors for the zones on the INTEGRA 128-WRL control panel mainboard
can be programmed:
using the keypad, in the service mode, by means of EOL R1 RESISTOR and EOL R2
RESISTOR
functions (STRUCTURE HARDWARE EOL R1 RESISTOR / EOL R2 RESISTOR),
using the DLOADX program, in the Structurewindow, Hardwaretab, after clicking on
the control panel mainboard.
52


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Integra 24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Integra 24 in the language / languages: English as an attachment in your email.

The manual is 1,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Integra 24

Satel Integra 24 User Manual - English - 51 pages

Satel Integra 24 Installation Guide - English - 36 pages

Satel Integra 24 Quick start guide - German - 2 pages

Satel Integra 24 User Manual - German - 54 pages

Satel Integra 24 Additional guide - German - 121 pages

Satel Integra 24 Installation Guide - German - 38 pages

Satel Integra 24 Quick start guide - Dutch - 24 pages

Satel Integra 24 User Manual - Dutch - 52 pages

Satel Integra 24 Additional guide - Dutch - 121 pages

Satel Integra 24 Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info