699079
37
Zoom out
Zoom in
Previous page
1/114
Next page
SATEL INTEGRA 35
computer port to which the control panel is connected. Then, follow the procedure described
in section Starting the service mode “from pins”(p. 6).
Running the local programming from pins is not possible, if the DISABLE
DOWNLOADING option is enabled.
3.3.3 Finishing local programming
To end the local programming you can use the END DWNL-RS function ([service code]
DOWNLOADING END DWNL-RS).
The local programming function will be finished automatically after 255 minutes have elapsed
since the last use of the DLOADX program, and the service access was blocked or expired
during that time.
The local programming function must be disabled, if the control panel is to
communicate through the RS-232 port with an external analog modem, GSM module,
INT-GSM module or ETHM-1 / ETHM-1 Plus module (e.g. during remote
programming, event reporting, etc.).
3.4 Remote programming
3.4.1 Starting remote programming via modem
The control panel has a built-in 300 bps modem. The GSM communicator of
INTEGRA 128-WRL control panel supports sending data with the use of CSD technology, i.e.
at a rate of 9600 bps. In case of the other control panels, higher transmission rates can be
obtained after an external modem is connected. For information on how to connect the
external modem to the control panel please refer to the INSTALLER MANUAL. Initializing the
modem connection is possible, if there is a properly matched modem on the computer side
(see Table 4).
Configuration on control panel side Configuration on computer side
Built-in 300 bps modem Analog modem
External analog modem
Analog modem
GSM modem
External ISDN modem
ISDN modem
GSM modem
External or built-in GSM modem
Analog modem
GSM modem
Table 4. Selecting control panel and computer modems.
Communication can be established in several ways (shown in parentheses is information
about requirements on the control panel side):
1. Connection initialized from the DLOADX program (built-in modem 300 bps or external
analog modem). This method makes it possible to establish connection with the control
panel from any location. Establishing connection by this method is possible, if the
computer telephone number has not been programmed in the control panel.
2. Connection initialized from the DLOADX program, but the control panel calls back and
sets up the connection (built-in 300 bps modem or external analog modem). The control
panel may only be remotely programmed from a specified locality.
3. Connection initialized by means of SMS (INTEGRA 128-WRL control panel or SATEL
GSM module operating as an external modem).
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Integra 24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Integra 24 in the language / languages: English as an attachment in your email.

The manual is 1,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Integra 24

Satel Integra 24 User Manual - English - 51 pages

Satel Integra 24 Installation Guide - English - 36 pages

Satel Integra 24 Quick start guide - German - 2 pages

Satel Integra 24 User Manual - German - 54 pages

Satel Integra 24 Additional guide - German - 121 pages

Satel Integra 24 Installation Guide - German - 38 pages

Satel Integra 24 Quick start guide - Dutch - 24 pages

Satel Integra 24 User Manual - Dutch - 52 pages

Satel Integra 24 Additional guide - Dutch - 121 pages

Satel Integra 24 Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info