699073
110
Zoom out
Zoom in
Previous page
1/114
Next page
108 Programming SATEL
When programming the control commands, remember that:
the command can include from 4 to 16 alphanumeric characters,
the command may not contain diacritic characters and/or spaces,
the commands must be different (the same command must not be used for
controlling two zones, two functions, etc.),
the content of one command may not be used as a whole when programming the
content of another command. For example, with the zone1 and zone11 type
commands, the control panel will be unable to execute the latter one.
Zone violation [SMS -> z.viol.]
SMS the control command that can be sent in the SMS message to the control panel
telephone number in order to violate a zone (the zone will be violated after the SMS
message is received by the control panel). You can define up to 32 such control
commands and assign one zone to each of them.
Zone the alarm system zone which is to be violated after the control panel receives an
SMS message with the control command. The zone need not to exist physically, but the
wiring type programmed for it must be different from NO DETECTOR or FOLLOW OUTPUT.
Starting the function [SMS -> function]
SMS the control command that can be sent in the SMS message to the control panel
telephone number in order to run a function (the function will be started after the SMS
message is received by the control panel). You can define up to 8 such control commands
and assign one function to each of them.
Function the function which is to be started after the control panel receives an SMS
message with the control command. You can select one of the following functions:
arming in chosen mode,
disarming,
clearing alarm,
zone bypassing (inhibiting),
zone unbypassing,
activating MONO SWITCH type outputs,
activating BI SWITCH type outputs,
deactivating BI SWITCH type outputs,
switching over BI SWITCH type outputs.
Partitions for some functions (arming/disarming, alarm clearing) you must indicate the
partitions where the function will be executed.
Zones for some functions (bypassing/unbypassing zones) you must indicate the zones to
which the function applies.
Outputs for some functions (activating/deactivating outputs) you must indicate the outputs
which will be controlled by the function.
Name you can enter an individual name for the function. The name will be included in the
content of SMS message, with confirmation that the function has been executed.
Checking the system status
SMS [SMS check state] the control command that can be sent in the SMS message to the
control panel phone number to check the state (status) of partitions. Having received the
SMS message, the control panel will send in response an SMS message containing
information on the partition status.
110


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Integra 128 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Integra 128 in the language / languages: English as an attachment in your email.

The manual is 1,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Integra 128

Satel Integra 128 User Manual - English - 51 pages

Satel Integra 128 Installation Guide - English - 36 pages

Satel Integra 128 User Manual - German - 54 pages

Satel Integra 128 Additional guide - German - 121 pages

Satel Integra 128 Installation Guide - German - 38 pages

Satel Integra 128 Quick start guide - Dutch - 24 pages

Satel Integra 128 User Manual - Dutch - 52 pages

Satel Integra 128 Additional guide - Dutch - 121 pages

Satel Integra 128 Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info