Sign. new trouble [New trbl.sign.] with this option enabled, the keypad can audibly signal
the occurrence of a new trouble (if the TROUBLE MEMORY UNTIL REVIEW option is enabled).
New trouble signaling is cleared after the troubles have been reviewed by the user.
Show code entering [Show code ent.] with this option enabled, entering the code is
presented on the keypad display by asterisks.
Show keypad name [Name (2nd row)] with this option enabled, the keypad name is
presented in the lower line of the display.
Exit delay clearing enable [Fin.exit delay] with this option enabled, the exit delay time in
partitions with the EXIT DELAY CLEARING option enabled can be shortened after pressing in
turn the 9
keys.
Show viol. zones [Zone violation] with this option enabled, violating the CHIME signal
triggering zone result additionally in the zone name being displayed.
Auto-Arm delay countdown [Auto-arm delay] with this option enabled, the auto-arm delay
countdown in partition is signaled acoustically.
Displ. mode switching [Dspl.mode chg.] with the option enabled, you can toggle the
display between the standby mode and the partition status display mode by using the 9
key.
Show disarm messages [Show disarming] if this option is enabled, the keypad will inform
about disarming with a displayed message at all times. If the option is disabled only in
case of disarming from the given keypad.
Show arm messages [Show arm] if this option is enabled, the keypad will inform about
arming with a displayed message (irrespective of how the system was armed).
Communication RS if this option is enabled, it is possible to connect a computer with
GUARDX program to the LCD keypad RS-232 port.
Quick control [Control (8#)] if this option is enabled, the OUTS CONTROL user function can
be started by pressing in turn the 8 keys (without the need to enter the user code).
Zones
For each of the keypad zones can be defined whether it will be used or not.
Auto-backlight
If the backlight of display or keys is to be turned on automatically, you can define whether
and which event will additionally turn on the backlight:
Nobacklight will be turned on only when pressing any key.
Viol. of zonebacklight will be additionally turned on when the selected zone is violated.
Entry delay in part. backlight will be additionally turned on when starting the entry delay
countdown in the selected partition.
Tamper signaled in part. [Tamper in part.] partition where alarm will be triggered in the
event of keypad tamper, triggering the alarm from keypad etc.
8.1.2 Volume/filter
You can adjust the volume level for INT-KLCD, INT-KLCDR and INT-KLFR keypads.
Volume volume level of the beeps generated during keypad operation (key pressing,
confirmation of performed operation, etc.).
Volume chimevolume level of the beeps generated after zone violation (CHIME).
Volume entry delayvolume level of the entry delay beeps.
Volume exit delayvolume level of the exit delay beeps.
Volume firevolume level of the fire alarm beeps.
Volume alarmvolume level when signaling burglar, panic and medical alarms
83


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Integra 128 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Integra 128 in the language / languages: English as an attachment in your email.

The manual is 1,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Integra 128

Satel Integra 128 User Manual - English - 51 pages

Satel Integra 128 Installation Guide - English - 36 pages

Satel Integra 128 User Manual - German - 54 pages

Satel Integra 128 Additional guide - German - 121 pages

Satel Integra 128 Installation Guide - German - 38 pages

Satel Integra 128 Quick start guide - Dutch - 24 pages

Satel Integra 128 User Manual - Dutch - 52 pages

Satel Integra 128 Additional guide - Dutch - 121 pages

Satel Integra 128 Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info