699073
62
Zoom out
Zoom in
Previous page
1/114
Next page
60 Programming SATEL
4.3.9 Groups of partitions
You can define up to 16 partition groups which will be controlled using the 80. ARMING,
81. DISARMING and 83. CLEARING ALARM type zones. The partition groups can be defined:
using the keypad, in the service mode, by means of the GROUPS function (ZONES
GROUPS).
using the DLOADX program, in the Zoneswindow, Arm/Disarm Groupstab.
4.3.10 Zone testing
Using the function available in the service mode menu in the keypad (ZONES TEST), you
can test the zones. Information on violation or tamper of the zone is displayed and signaled
by beeps in keypad (violation 5 short beeps; tamper 1 long beep; masking 3 long
beeps). Additionally, the function allows selection of a system output which will be used for
signaling during the test (zone violation will activate the output for 0.4 second, tamper for
1,6 seconds, masking – for 3 seconds).
Violation/tamper/masking of the zone during the test will not trigger the response
programmed for the control panel zone.
Select a zone for testing from the list and press the or key. The output allocated
for signaling will stop doing its present duty (if it was active, it will be disabled) until the
zone test is completed (the key pressed).
The output used for signaling is only remembered until exiting the TEST function. When
the TEST function is re-started, the output must be selected again.
If wireless sirens are used in the system and any output is selected for signaling, after
selecting a zone for testing from the list and pressing the or key, in the wireless
sirens the signaling will be unblock (which is normally blocked for the service mode
duration).
If the output selected for signaling controls the wireless siren, it should be borne in
mind that the command to block/unblock signaling is sent out during polling. This
results in a delay whose duration depends on the programmed response period. Also
in case of the ASP-205 siren signaling is only triggered during the polling period.
5. Outputs
The system supports the following outputs:
hardwired on the control panel electronics board and in expanders. The number of
available hardwired outputs is determined by the control panel during identification
procedure.
wireless in the INTEGRA 128-WRL control panel or after connecting the ABAX 2 /
ABAX wireless system controller. The number of available wireless outputs depends on
the number of wireless devices registered in the system and is determined during the
procedure of adding wireless devices.
virtual the outputs which do not exist physically, but can be used e.g. for execution of
logical functions.
Programming of the outputs is possible:
using the keypad, in the service mode, by means of the functions available in the OUTPUTS
submenu,
using the DLOADX program, in the Outputswindow.
62


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel Integra 128 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel Integra 128 in the language / languages: English as an attachment in your email.

The manual is 1,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel Integra 128

Satel Integra 128 User Manual - English - 51 pages

Satel Integra 128 Installation Guide - English - 36 pages

Satel Integra 128 User Manual - German - 54 pages

Satel Integra 128 Additional guide - German - 121 pages

Satel Integra 128 Installation Guide - German - 38 pages

Satel Integra 128 Quick start guide - Dutch - 24 pages

Satel Integra 128 User Manual - Dutch - 52 pages

Satel Integra 128 Additional guide - Dutch - 121 pages

Satel Integra 128 Installation Guide - Dutch - 35 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info