699062
34
Zoom out
Zoom in
Previous page
1/37
Next page
32 Installer Manual SATEL
expander). The changes in numeration will only be valid until you start the expander
identification function again.
7. Replacing the battery on control panel mainboard
It is recommended that the status of clock and RAM memory backup battery be checked e.g.
during periodical inspections, at least every 5 years. The battery life depends on:
temperature,
humidity,
time during which the control panel power supply is off,
battery self-discharge.
If the battery is low, it must be replaced with a new one of the same type (CR1220).
Be particularly careful during replacement of the battery. The manufacturer is
not liable for the consequences of incorrect installation of the battery.
Replace the battery when the control panel power supply (main or backup) is on.
If you remove the battery when the control panel power supply is off, the data
stored in the RAM memory (event log, user data, clock settings) will be lost.
8. Specifications
8.1 Control panel
Supply voltage ................................................................................... 18 V AC ±15%, 50-60 Hz
Recommended transformer ............................................................................................. 40 VA
Standby current consumption from AC mains ................................................................ 120 mA
Maximum current consumption from AC mains ............................................................. 300 mA
Standby current consumption from battery .................................................................... 280 mA
Maximum current consumption from battery .................................................................. 600 mA
Battery failure voltage threshold ............................................................................... 11 V ±10%
Battery cut-off voltage ........................................................................................... 10.5 V ±10%
Battery charging current .......................................................................................... 400/800 mA
Power supply output current .................................................................................................2 A
Power supply output voltage range .................................................................... 10.5…14 V DC
Current-carrying capacity, high-current programmable outputs ................................. 2 A ±10%
Current-carrying capacity, low-current programmable outputs ......................................... 50 mA
Current-carrying capacity, +KPD output .................................................................. 0.5 A ±10%
Current-carrying capacity, +EX output .................................................................... 0.5 A ±10%
Current-carrying capacity, AUX output .................................................................... 0.5 A ±10%
ABAX system operating frequency band ............................................ 868.0 MHz ÷ 868.6 MHz
Radio communication range (in open area) ............................................................ up to 500 m
Number of supported wireless devices .................................................................................. 48
Number of supported APT-200 / APT-100 keyfobs .............................................................. 248
Hardwired programmable zones .............................................................................................. 8
Maximum number of programmable zones .......................................................................... 128
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel integra 128-WRL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel integra 128-WRL in the language / languages: English as an attachment in your email.

The manual is 0,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel integra 128-WRL

Satel integra 128-WRL User Manual - English - 51 pages

Satel integra 128-WRL Additional guide - English - 114 pages

Satel integra 128-WRL Installation Guide - German - 2 pages

Satel integra 128-WRL Additional guide - German - 121 pages

Satel integra 128-WRL User Manual - German - 38 pages

Satel integra 128-WRL Additional guide - Dutch - 121 pages

Satel integra 128-WRL User Manual - Dutch - 52 pages

Satel integra 128-WRL Quick start guide - Dutch - 24 pages

Satel integra 128-WRL Installation Guide - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info