Schema der Verbindungen im Alarmsystem
CA-6 plus.
Ausgang OUT4
Ausgang OUT5
DB-15
Sicherung 250V/2A
zur "+" Akkumulator
zur Klemme AC der Hauptplatine
zur Masse COM (neben der Klemme OUT1)
1
2
9
15
8
Ansicht des Steckplatzes im Sender NR2-DSC
Port der Schwachstromausgänge
der Zentrale
CA-6 plus
14
13
12
(PGM)
(TAKT)
Masse
Niederfrequenz-Signal
Auslösen der Wiedergabe
+ Speisespannung
Zentralenplatine
Abhorchen der Fernsprechleitung
Die Ausgänge OUT1, OUT2 und OUT3 müssen mit einem
Widerstand von 2,2 k belastet sein.
OUT1 COM OUT2 COM OUT3 COM
+12 V
2,2A
2,2A
BEGERENZER
2,2A
BELASTUNG
+KPD
1,5A
BEGERENZER BEGERENZER
BEGERENZER
BELASTUNG BELASTUNG
OUT4
Speisung +12V
OUT5
Belastung
50mA
COM
+12V
P
OUT n
Relais
-Ausgang
Ausgang
zur Masse
+12V
R
OUT n
+ Ucc
Sicherung (T 3,15 A) in
der Schaltung des Akkus
(rot)
(schwarz)
Leitungen des Akkus
12V/7Ah
Transformator 17...24V AC
Telefon
Fernsprechleitung
(extern)
RESET
Übertragungs-
einrichtung
CA-6 plus
GNDTAMPCNC+12
COM
Zn COM
MELDER
SPEISUNG
+12V
KONFIGURATION 2EOL
2x1.1K
GNDTAMPCNC+12
COM
Zn
KONFIGURATION EOL FÜR DEN TYP NC
2.2K
24H
COM
GNDTAMPCNO+12
COM
Zn
KONFIGURATION EOL FÜR DEN TYP NO
2.2K
COM
GNDTAMPCNC+12
COM
Zn
KONFIGURATION FÜR DEN TYP NC ODER NO
COM
MELDER
SPEISUNG
+12V
SABOTAGELINIE
24H
SABOTAGELINIE
SPEISUNG
+12V
SPEISUNG
+12V
24H
SABOTAGELINIE
MELDER
MELDER
FÜR DEN TYP NC ODER NO
COM +KPD DATA CLK Z1 COM Z2
+12 CLK Z1 Z2DATA COM
Bedienteil
Eingang 7 Eingang 8
Hauptplatine
CTL Z2
Platine der Zentrale
CA-6 plus
Telefonport
der Zentrale
Port
des Sprachgenerators
zum Modem
Widerstand
220 Ω
(+12V)
(COM)
T-1
R-1
RING
TIP
lokale Parametrierung
Eingang CTL
RS232
TTL
80


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel CA-6 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel CA-6 in the language / languages: German as an attachment in your email.

The manual is 0,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel CA-6

Satel CA-6 Additional guide - English - 40 pages

Satel CA-6 Quick start guide - English - 8 pages

Satel CA-6 Installation Guide - English - 36 pages

Satel CA-6 Additional guide - German - 19 pages

Satel CA-6 User Manual - German - 19 pages

Satel CA-6 User Manual - German - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info