16 Settings list CA-5
FS 72 – AC LOSS REPORTING DELAY
|__|__|__|#
program from 0 do 255 minutes
default|0|1|0|#
Note: Entering the „0” value will block sending the „AC loss” event code, while during review
of the current troubles, information on such a failure will be displayed on the LEDs.
FS 73 – TELEPHONE LINE VOLTAGE LOSS REPORTING DELAY
|__|__|__|#
program from 0 to 99 minutes default|0|0|0|#
Note: Entering the 0 value will block reporting troubles of the „telephone line voltage loss”
type.
7. RESTARTS
Performance of the functions FS 74 and FS 75 will restore default values of the parameter
settings. The special way these functions (request to confirm execution of the function with
the key [1]) are executed protects the settings against an accidental deletion.
FS 74 – CLEAR SETTINGS
After calling the function, the LEDs 2 to 4 will light up. Press the [1] key to restore the default
settings. The function also resets the names of users and zones.
FS 75 – CLEAR CODES
After calling the function, the LEDs 1, 3, 4 and 5 will light up. Press the [1] key to restore the
default settings.
FS 76 – CLEAR MONITORING CODES AND IDENTIFIER
All the codes are pre-programmed according to the default settings (see: FS 56 to FS 68).
The purpose of the function is to quicken the process of programming the selected
monitoring codes. An earlier activation of the function makes unnecessary the individual
deletion of the codes not sent to the station. The deletion consists in programming the zero
code.
After calling the function, the LEDs 1, 2, 4 and 5 will light up. Press the [1] key to reset all the
control panel monitoring codes and identifier.
FS 77 – LOCAL DOWNLOADING (local communication)
Note: All the changes introduced in the process of communication become valid as soon as
they are uploaded to the panel, except for some parameters (zone sensitivity, zone
types, telephone messaging options), which become valid after the communication is
ended or a full minute is counted by the panel (after the end of uploading).
FS 78 – RS-232 DOWNLOADING
Calling the function starts data exchange between the panel and the computer via the
RS-232 port.
Note:
To connect the ports of the control panel and the computer, use the special cable of
SATEL make, which is designed for conversion of the TTL (0V, +5V) standard signal into
the RS-232 (-12 V, +12 V) standard. The cable enables two-way data transmission.
In case of laminate version 4.0 and up (PCB with RJ socket), the cable with DB9FC/RJ
designation is necessary. In case of an earlier version of laminate, the cable with
DB9FC/PIN3 designation is needed.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Satel CA-5 Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Satel CA-5 Plus in the language / languages: English as an attachment in your email.

The manual is 0,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Satel CA-5 Plus

Satel CA-5 Plus User Manual - English - 24 pages

Satel CA-5 Plus Installation Guide - English - 27 pages

Satel CA-5 Plus User Manual - German - 24 pages

Satel CA-5 Plus Additional guide - German - 20 pages

Satel CA-5 Plus User Manual - German - 24 pages

Satel CA-5 Plus Installation Guide - German - 28 pages

Satel CA-5 Plus User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info