5
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks: Rating conditions are:
Cooling: Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
Heating: Indoor air temperature 20°C D.B.
Outdoor air temperature 7°C D.B. / 6°C W.B.
2. SPECIFICATIONS
2-1. Unit Specifications
Indoor Unit SAP-KRV93EH
Outdoor Unit SAP-CRV93EH
Power Source 220 – 240V Single-phase 50Hz
Performance Cooling Heating
Capacity kW 2.65 (0.9 – 3.2) 3.60 (0.9 – 5.0)
BTU/h 9,000 (3,100 – 10,900) 12,300 (3,100 – 17,100)
Air circulation (High) m
3
/h 480 530
Moisture removal (High) Liters/h 1.6 —
Electrical Rating Cooling Heating
Available voltage range V 198 – 264
Running amperes A 3.86 (1.28 – 5.88) 4.81 (1.21 – 6.47)
Power input W 755 (250 – 1,150) 995 (250 – 1,340)
Power factor % 85 90
C.O.P. W/W 3.51 3.62
Compressor locked rotor amperes A 15
Features
Controls / Temperature control Microprocessor / I.C. thermister
Control unit Wireless remote control unit
Timer ON / OFF 24 hours & Daily program, 1-hour OFF
Fan speeds Indoor / Outdoor 3 and Auto / 1 (Hi)
Airflow direction (Indoor) Horizontal Manual
Vertical Auto
Air filter Washable, Anti-Mold
Compressor Rotary (DC inverter)
Refrigerant / Amount charged at shipment g R410A / 950
Refrigerant control Electric expansion valve
Operation sound Indoor: Hi / Me / Lo dB-A 34 / 31 / 28 34 / 31 / 28
Outdoor: Hi dB-A 46 47
Refrigerant tubing connections Flare type
Max allowable tubing length at shipment m 7.5
Refrigerant Narrow tube mm (in.) 6.35 (1/4)
tube diameter Wide tube mm (in.) 9.52 (3/8)
Refrigerant tube kit / Accessories Optional / Air clean filter
Voltage Rating 230V
Dimensions & Weight Indoor Unit Outdoor Unit
Unit dimensions Height mm 285 548
Width mm 825 720
Depth mm 189 265
Package dimensions Height mm 350 600
Width mm 900 856
Depth mm 255 362
Weight Net kg 9.0 34.0
Shipping kg 11.0 36.0
Shipping volume m
3
0.080 0.186