489455
72
Zoom out
Zoom in
Previous page
1/77
Next page
21
Adjusting the Airflow Direction
1. Horizontal The horizontal airflow can be adjusted by moving the vertical vanes with your
hands to the left or right.
When the humidity is high, the vertical vanes should be in the front
position during the cooling or dehumidifying operation. If the vertical
vanes are positioned all of the way to the right or left, condensation
may begin to form around the air vent and drip down.
2. Vertical The vertical airflow can be adjusted by moving the flap with the remote
control unit. Do not move the flap with your hands. Confirm that the remote
control unit has been turned on. Use the FLAP button to set either the sweep
function or one of the six airflow direction settings.
The flap automatically closes when the unit is off.
During the heating operation, the fan speed will be very low and the flap
will be in the horizontal position (position ) until the air being blown out
of the unit begins to warm. Once the air warms up, the flap position and
fan speed change to the settings specified with the remote control.
Use the FLAP button on the remote control to adjust the position of
the flap. If you move the flap by hand, the flap position according to
the remote control and the actual flap position may no longer match.
If this should happen, shut off the unit, wait for the flap to close, and
then turn on the unit again; the flap position will now be normal
again.
Do not have the flap pointed down during cooling operation.
Condensation may begin to form around the air vent and drip down.
CAUTION
A. Sweep function
The flap starts moving up and down to
deliver air over the sweep range.
C. Auto flap function
The flap is set to the recommended
position.
B. Setting the airflow manually
Referring to the above illustration, use the
FLAP button to set the airflow direction
within the range used during the heating,
cooling, or dehumidifying operation.
COOL
DRY
FAN
HEAT
SWEEP
SWEEP
NOTE
CAUTION
OI-671-21EG
01_SAP-KRV93EH_EN.fm Page 21 Thursday, February 12, 2004 12:10 PM
72


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sanyo SAP-CRV93EH at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sanyo SAP-CRV93EH in the language / languages: English as an attachment in your email.

The manual is 2,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info