Chapter 5Maintenance — Light source/temperature/lter indicators
ENGLISH - 183
Temperature indicator <TEMP>
Indicator status Lighting in red
Blinking in red
(2 times)
Blinking in red
(3 times)
Status Warm-up status
Internal temperature is high
(warning).
Internal temperature is high
(standby status).
The cooling fan has
stopped.
Cause
f Did you turn on the power
when the temperature
was low (around 0 °C
(32 °F))?
f Is the air intake/exhaust port blocked?
f Is the room temperature high?
f Is the lter indicator <FILTER> lit?
Solution
f Wait at least ve minutes
in the current status.
f Install the projector in a
location with the operating
environment temperature
between 0 °C (32 °F) and
50 °C (122 °F)
*1
.
f Remove any objects that are blocking the air intake/
exhaust port.
f Install the projector in a location with the operating
environment temperature between 0 °C (32 °F) and
50 °C (122 °F)
*1
, and ambient humidity between 10 %
and 80 % (no condensation).
f Clean or replace the air lter unit. (x page 184)
f Turn the <MAIN POWER>
switch to <OFF>
(x page 63), and
consult your dealer.
*1 The operating environment temperature should be between 0 °C (32 °F) and 45 °C (113 °F) if the projector is used at an altitude between 1 400 m
(4 593') and 4 200 m (13 780') above sea level. When [OPERATING MODE] in the [PROJECTOR SETUP] menu [OPERATION SETTING] is
set to [ECO], [LONG LIFE1], [LONG LIFE2], or [LONG LIFE3], the operating environment temperature should be between 0 °C (32 °F) and 45 °C
(113 °F), and when the Smoke Cut Filter is used, it should be between 0 °C (32 °F) and 40 °C (104 °F) regardless of the altitude.
When [OPERATING MODE] in the [PROJECTOR SETUP] menu [OPERATION SETTING] is set to [ECO], [LONG LIFE1], [LONG LIFE2], or
[LONG LIFE3], the projector cannot be used at an altitude of 2 700 m (8 858') or higher above sea level. When the Smoke Cut Filter is used, the
projector cannot be used at an altitude of 1 400 m (4 593') or higher above sea level.
Note
f If the temperature indicator <TEMP> is still lit or blinking after taking the measures, ask your dealer for repair.
Filter indicator <FILTER>
Indicator status Lighting in red Blinking in red
Status
The lter is clogged.
The temperature inside or outside the projector is abnormally high.
The air lter unit is not
attached.
Cause f Is the air lter unit dirty?
f Is the air intake/exhaust
port blocked?
f Is the projector used at
an altitude of 4 200 m
(13 780')
*1
or higher
above sea level?
f Is the air lter unit
attached?
Solution
f Clean or replace the air
lter unit. (x page 184)
f Remove any objects that
are blocking the air intake/
exhaust port.
f Do not use the projector
at an altitude of 4 200 m
(13 780')
*1
or higher
above sea level.
f Attach the air lter unit.
*1 When [OPERATING MODE] in the [PROJECTOR SETUP] menu [OPERATION SETTING] is set to [ECO], [LONG LIFE1], [LONG LIFE2], or
[LONG LIFE3], the projector cannot be used at an altitude of 2 700 m (8 858') or higher above sea level. When the Smoke Cut Filter is used, the
projector cannot be used at an altitude of 1 400 m (4 593') or higher above sea level.
Note
f If the lter indicator <FILTER> is still lit or blinking after taking the measures, ask your dealer for repair.
183


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sanyo PT-RS11K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sanyo PT-RS11K in the language / languages: English as an attachment in your email.

The manual is 26,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sanyo PT-RS11K

Sanyo PT-RS11K User Manual - German - 223 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info