Chapter 4Settings — [PROJECTOR SETUP] menu
140 - ENGLISH
[OFF] Does not return the response when an ID is designated as GROUP.
Note
f When [INPUT SELECT] is set to [DIGITAL LINK], communication using that serial terminal is available only when the corresponding device
(such as the optional DIGITAL LINK output supported device (Model No.: ET-YFB100G, ET-YFB200G)) is connected to the <DIGITAL LINK/
LAN> terminal.
f When transferring logos via the optional DIGITAL LINK output supported device (Model No.: ET-YFB100G, ET-YFB200G), setting for “NO
SIGNAL SLEEP” of the DIGITAL LINK output supported device should be set to “OFF” to avoid interruption of communication.
f When [INPUT SELECT] is set to [DIGITAL LINK], communication speed for input is xed to 9 600 bps and the parity is xed to “NONE”.
[REMOTE2 MODE]
You can set the <REMOTE 2 IN> terminal.
1) Press as to select [REMOTE2 MODE].
2) Press qw to switch the item.
f The items will switch each time you press the button.
[DEFAULT]
Uses pin assignment of the <REMOTE 2 IN> terminal in standard setting. (x page 203)
[USER] Changes the setting of the <REMOTE 2 IN> terminal.
f When [USER] is selected, proceed to Step 3).
3) Press the <ENTER> button.
4) Press as to select one from [PIN2] to [PIN8], and press qw to switch the setting.
[FUNCTION BUTTON]
Set the function of the <FUNCTION> button on the remote control.
1) Press as to select [FUNCTION BUTTON].
2) Press the <ENTER> button.
f The [FUNCTION BUTTON] screen is displayed.
3) Press as to select a function.
[DISABLE] Disables the <FUNCTION> button.
[P IN P]
Switches the [P IN P] setting ([OFF], [USER1], [USER2], or [USER3]). (x page 146)
[SUB MEMORY]
Displays the sub memory list. (x page 151)
[SYSTEM SELECTOR]
Switches the [SYSTEM SELECTOR] setting. (x page 88)
[SYSTEM DAYLIGHT VIEW]
Switches the [SYSTEM DAYLIGHT VIEW] setting. (x page 86)
[FREEZE]
Temporarily pauses the image. (x page 123)
[WAVEFORM MONITOR]
Displays the waveform of the input signal. (x page 123)
[LENS MEMORY LOAD]
Loads the registered lens memory. (x page 141)
[LEFT/RIGHT SWAP]
Switches the [LEFT/RIGHT SWAP] setting. (x page 103)
[PROJECTION METHOD]
Switches the [PROJECTION METHOD] setting. (x page 125)
4) Press the <ENTER> button.
[LENS CALIBRATION]
Detect the lens shift limit value of the projector and set the home position and the ET-D75LE90 lens standard
position automatically.
1) Press as to select [LENS CALIBRATION].
2) Press qw to switch the item.
f The items will switch each time you press the button.
[NORMAL]
Select this item when anything other than the Fixed-focus Lens (Model No.: ET-D75LE90) is used.
Move the lens to the home position after completing the calibration.
[D75LE90]
Select this item when the Fixed-focus Lens (Model No.: ET-D75LE90) is used.
Move the lens to the ET-D75LE90 lens standard position after completing the calibration.
140


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sanyo PT-RS11K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sanyo PT-RS11K in the language / languages: English as an attachment in your email.

The manual is 26,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sanyo PT-RS11K

Sanyo PT-RS11K User Manual - German - 223 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info