Warning – correct use of rotary pumps
1-Proper Alignment of Pump and Motor
On occasion the noise of a motor-pump assembly is caused by a poor alignment.
When the coupling between motor and pump is rigid, the pump rotor and the motor rotor may be out of axis. If this condition is maintained over time the
most likely damage is seizure of the pump.
An ef cient solution of this problem is the use of an elastic cou-
pling between pump and motor. Fluid-o Tech supplies an optional
kit code N. 10051020.
2-Quality of Water.
Tight mechanical tolerances of components and materials used
for rotary vane pumps require a very clean water, free from su-
spended particles. Sand, deposits on connecting pipes or the
resins of the sweetener, when owing through the pump, may
scratch graphite parts causing problems of insuf cient pressure
and ow rate.
If a closed loop hydraulic circuit is not available to guarantee a clean water and no sources of contamination Fluid-o-Tech recommend to install a 5-10
micron lter between the sweetener and the pump.
Recommended lter: food approved polipropilene wire cartridge.
Keep the lter clean.: an upstream dirty lter will create cavitation and the pump will break shortly (see section 4).
3-Dry operation
Rotary vane pumps may operate in dry condition only for a very short time- few seconds!
Without a proper water cooling the temperature of the mechanical seal will increase very quickly with resulting breakage. The most likely impact is a remar-
kable leak visible from the four drain holes close to the motor clamp . For potential lack of feed from city water line Fluid-o-Tech recommend the installation
of a minimum pressure safety switch upstream from the pump.
In case of feed from a tank install on the tank a minimum level switch.
4-Cavitation
Cavitation shows when feed ow rate does not match the pump design requirement: most frequent causes are dirty lters, small diameter pipes, more
users on the same line.
Opening of the safety valve (generally installed upstream from pump and lter) must happen
before the pump start up. This will avoid cavitation. For the same reason closing of the safety valve must be delayed after the pump shut down.
The most noticeable effect is an increase of noise. If cavitation continues the impact is the same as of dry operation.
5-Back Feed of Hot Water
If a non return valve between the pump and the hot water vessel is defective the pump may come in contact with hot water(90-100°C). Dimensional varia-
tions of components will cause seizure of the pump.
6) Wrong connections
Pumps connectors are 3/8”NPT(conical) or 3/8” GAS(cylindrical).
Connectors with thread different from the recommended type are occasionally used. Sealing is made with a glue or with te on tape. If the connector is
forced it is possible to create beards; if excess sealing glue is used the extra quantity of glue may enter into the pump body.
In both cases it is likely to create a damage.
7) Pressure strokes
To avoid pressure strokes opening of solenoid valves installed downstream must happen before the start of the pump. For the same reason closing of the
valve must be delayed after stopping of the pump.
A pressure stroke may break graphite parts and damage mechanical seal causing blockage of the pump and leaks.
8) Handling
A crash on the oor may create deformations that will jeopardize the tight mechanical tolerances of the pump components. For the same reason be very
careful when clamping the pump to mount or demount connectors.
9) Scale build up
Scale deposits will quickly show on inner components when using hard water, not sweetened with ion exchange resins.
Scale formation increases when the pressure relief valve is used as ow rate regulator: the rate of scale deposition increases with increasing of closed loop
circulation.
Scale deposits cause an increase of torque, occasional seizure of the pump or a reduction of operating pressure because the pressure relief valve cannot
work properly.
To minimize this problem Fluid-o-Tech suggest to use pumps with ow rate matching the hydraulic circuit features.
In some circuits it is advisable to periodically remove scale with a chemical treatment.
ENGLISH
7


Need help? Post your question in this forum.

Forumrules
1

Forum

sanremo-capri

Reset search

  • I have a San Remo Capri Deluxe 2 group machine.
    One side had stopped working for several weeks and now the other side is playing up.
    Machine not pumping water through the group. A few drops dribble through but appears pump is not operating.
    Anybody have some input on what is wrong here and how to fix it? Submitted on 13-7-2022 at 08:13

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sanremo Capri at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sanremo Capri in the language / languages: English as an attachment in your email.

The manual is 2,21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info