The bar graph in the display and the scale on the unit
indicate the range of the blood pressure which has been
recorded. An accoustic evaluation of your measurement
also follows.
If the values for systolic and diastolic pressure are in two
different WHO ranges (e.g. systolic in the high-normal
range and diastolic pressure in the normal range) the gra-
phic WHO classification on the unit indicates the higher
range (high-normal in the example described).
6. Saving, retrieving and deleting results
The results of each successful measurement are stored
together with date and time. With more than 60 items of
measured data, the earliest items of data measured are
lost.
In order to retrieve measurement results again, press the
memory button ‚MEM‘. The instrument first displays the
number of memory spaces occupied and then automati-
cally switches to the last saved test result. All the stored
measured values are also acoustically output.
Pressing the memory button ‚MEM‘ again outputs the
further measurement values with date and time.
You can clear the memory by holding down the memory
button ‚MEM‘ for 3 seconds.
7. Error messages/troubleshooting
In case of faults, the ‚EE‘ message appears in the display.
Error messages can occur when
1. inflation pressure is higher than 300 mmHg,
2. blood pressure is unusually high or low,
3. you move or talk during the measurement,
4. the cuff tube is not inserted properly,
5. the cuff is inflated for longer than 30 seconds.
In the above cases, you must repeat the measure ment.
Make sure that the cuff tube is properly inserted and that
you do not move or talk. Re-insert the batteries if neces-
sary, or else replace them.
Range of blood pressure values Systolic Diastolic Measure
(in mmHg) (in mmHg)
Grade 3: Severe hypertension >=180 >=110 Seek medical advice
Grade 2: Moderate hypertension 160-179 100-109 Seek medical advice
Grade 1: Mild hypertension 140-159 90-99 Have it checked regularly by doctor
High-normal 130-139 85-89 Have it checked regularly by doctor
Normal 120-129 80-84 Check it yourself
Optimal <120 <80 Check it yourself
Source: WHO, 1999
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sanitas sbm 19 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sanitas sbm 19 in the language / languages: English, German, French, Spanish as an attachment in your email.

The manual is 0,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info