708299
25
Zoom out
Zoom in
Previous page
1/92
Next page
25
Use
The hood is conceived for the suction of cooking fumes and steam and is destined only
for domestic use.
The hood is designed to be used either for exhausting or filter version.
Extraction version
In this case the fumes are conveyed outside of the building by means of a special pipe
connected with the connection ring located on top of the hood.
CAUTION!
The exhausting pipe is not supplied and must be purchased apart.
Diameter of the exhausting pipe must be equal to that of the connection ring.
CAUTION!
If the hood is supplied with active charcoal filter, then it must be removed.
Connect the hood and discharge holes on the walls with a diameter equivalent to the air
outlet (connection flange).
Using the tubes and discharge holes on walls with smaller dimensions will cause a
diminution of the suction performance and a drastic increase in noise.
Any responsibility in the matter is therefore declined.
! Use a duct of the minimum indispensable length.
! Use a duct with as few elbows as possible (maximum elbow angle: 90°).
! Avoid drastic changes in the duct cross-section.
Filtration version
The aspirated air will be degreased and deodorised before being fed back into the
room.
In order to use the hood in this version, you have to install a system of additional
filtering based on activated charcoal.
Installation
The minimum distance between the supporting surface for the cooking equipment on
the hob and the lowest part of the range hood must be not less than 50cm from electric
cookers and 65cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a greater distance, this must be
adhered to.
Electrical connection
The mains power supply must correspond to the rating indicated on the plate situated
inside the hood. If provided with a plug connect the hood to a socket in compliance with
current regulations and positioned in an accessible area, after installation. If it not fitted
with a plug (direct mains connection) or if the plug is not located in an accessible area,
after installation, apply a double pole switch in accordance with standards which
assures the complete disconnection of the mains under conditions relating to over-
current category III, in accordance with installation instructions.
WARNING!
Before re-connecting the hood circuit to the mains supply and checking the efficient
function, always check that the mains cable is correctly assembled.
The hood is provided with a special power cable ; if the cable is damaged, request a
new one from Technical Service.
Mounting
Before beginning installation:
Check that the product purchased is of a suitable size for the chosen installation
area.
Remove the charcoal (*) filter/s if supplied (see also relative paragraph). This/these
is/are to be mounted only if you want lo use the hood in the filtering version.
Check (for transport reasons) that there is no other supplied material inside the
hood (e.g. packets with screws (*), guarantees (*), etc.), eventually removing them
and keeping them.
This hood is designed for fitting in a cabinet or on some other support.
Maintenance
Cleaning
Clean using ONLY a cloth dampened with neutral liquid detergent. DO NOT CLEAN
WITH TOOLS OR INSTRUMENTS. Do not use abrasive products. DO NOT USE
ALCOHOL!
Always wear work gloves for all maintenance operations.
Grease filter
Fig. 8-13
Traps cooking grease particles.
The grease filter must be cleaned once a month using non aggressive detergents,
either by hand or in the dishwasher, which must be set to a low temperature and a short
cycle. When washed in a dishwasher, the grease filter may discolor slightly, but this
does not affect its filtering capacity.
To remove the grease filter, pull the spring release handle.
Charcoal filter (Optional)
Fig. 12
It absorbs unpleasant odors caused by cooking.
The saturation of the charcoal filter occurs after more or less prolonged use,
depending on the type of cooking and the regularity of cleaning of the grease filter.
In any case it is necessary to replace the cartridge at least every four months.
The charcoal filter may NOT be washed or regenerated.
Remove the grease filters.
Apply one charcoal filter each side and hook in onto the hood.
Refit the grease filter.
Buying charcoal filters
The Charcoal filter can be bought at Samsung Service Website and Service Center.
Please refer to the last page of manual.
Replacing lamps
Disconnect the appliance from the electricity.
Warning! Prior to touching the light bulbs ensure they are cooled down.
Extract the drawer completely.
Remove the suction gril to access the lamp area.
Remove the damaged light and replace it with a new one (see the table below):
Lamp Power (W) Socket
3 E14
Voltage (V) Dimension (mm)
220-240
35x102 (Diameter
x Length)
ILCOS D Code
(according IEC 61231)
DRBB/C-3-220-240-E14-35/102
Put the grill back.
If the lights do not work, make sure that the lamps are fitted properly into their housings
before you call for technical assistance.
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Samsung NK24M1030IS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Samsung NK24M1030IS in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 2,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info