INSTALLATION07
Evacuating the connected pipes
1. Connect each assembly pipe to the appropriate valve on the outdoor unit and
tighten the are nut.
2. Tighten the are nut rst with your hands, and then with a torque wrench,
applying the following torque.
Outdoor unit Indoor unit
Gas pipe side
Liquid pipe side
• Excessivetorquecanbecauseofgasleakage.
3. Connect the charging hose of the low-pressure side of manifold gauge to a
gas service port as seen in the picture.
4. Open the valve of the low pressure side of manifold gauge counterclockwise.
5. Evacuate the air in the connected pipes using the vacuum pump for about
15 minutes.

Make sure that pressure gauge shows -0.1MPa(-76cmHg) after about
10 minutes.
This procedure is very important to avoid a gas leak.

Close the valve of the low pressure side of manifold gauge clockwise.

Turn o the vacuum pump.

Check for 2 minutes if there is any pressure change.

Remove the hose of the low pressure side of manifold gauge.
6. Set a valve cork of liquid and gas service port to the open position.
Vacuum
Pump
Manifold gauge
Valve
Gas service port
<Low pressure>
Liquid service port
<High pressure>
(Backward flowing
prevention)
• TheremainingairintheRefrigerationcycle,whichcontainsmoisture,maycausemalfunctiononthecompressor.
• Alwayscontacttheservicecenteroraprofessionalinstallationagencyforproductinstallation.
Addrefrigerantchargeaccordingtotablebelow:
If you use a pipe longer than 5m,
A g of refrigerant R-22 must be added for each extra meter.
If you use a pipe shorter than 5m,
The evacuating time is normal.
Refer to the Service Manual for further details.
Adding Refrigerant
Model A

09/12

10

18/24

20
Outer
Diameter
Torque
N•m kgf•cm
ø6.35 mm
14~18 140~180
ø9.52 mm
34~42 350~430
ø12.70 mm
49~61 500~620
ø15.88 mm
68~82 690~830
SG_GOOD_A3050_IB&IM_EN_DB68-04398A_New.indd 47 8/1/2014 10:37:09 AM
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Samsung AR5000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Samsung AR5000 in the language / languages: English as an attachment in your email.

The manual is 20,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Samsung AR5000

Samsung AR5000 User Manual - Dutch - 30 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info